Comparison of standard and task-specific enhancement of Digora®storage phosphor images for approximal caries diagnosis
Authors:
- A MøystadAMA Møystad
- Db SvanæsDSDb Svanæs
- Pf van der SteltPSPf van der Stelt
- H-G GröndahlHGH-G Gröndahl
- A WenzelAWA Wenzel
- Fc van GinkelFGFc van Ginkel
- B KullendorffBKB Kullendorff
- H HintzeHHH Hintze
- Ta LarheimTLTa Larheim
- 1 November 2003
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 32 (6) , 390-396
Abstract
To compare approximal caries detection on Digora storage phosphor images pre-enhanced with the automatic "caries-specific Oslo enhancement procedure" ("Oslo-enhanced" method) and storage phosphor images individually enhanced by observers particularly experienced in digital imaging using standard brightness and contrast functions of the Digora system ("Digora-enhanced" method). Seven staff members from four oral radiology departments rated 240 approximal surfaces for caries with regard to lesion depth in the inner and outer half of the enamel and dentine, using a 5-point confidence scale. The observations were validated histologically. A receiver operating characteristic (ROC) analysis and an analysis of variance with three dependent variables (observer confidence, observer signed error and observer absolute error) were performed. The most evident difference between the methods as elucidated by the ROC analysis was the highly significant smaller interobserver and intraobserver variance with the Oslo-enhanced method for all but one observer. The methods were not different with regard to average diagnostic accuracy (A(z) values) as tested with paired t-tests, and there was no correlation between A(z) across methods. The method and lesion main effects, as well as the lesion by method interaction effect, were multivariately significant (P<0.001) in favour of the Oslo-enhanced method. On a univariate level, the method main effect was not significant for the absolute observer error (P=0.330). All other univariate effects were significant (P<0.001). The accuracy of approximal caries detection with Digora storage phosphor images pre-enhanced and images individually enhanced was similar, but interobserver and intraobserver variability improved with the Oslo-enhanced method. Since image manipulation is not performed with the Oslo-enhanced method, the increased speed of the diagnostic procedure combined with the improved observer variability would probably be even more pronounced for the general dental practitioner.Keywords
This publication has 20 references indexed in Scilit:
- A comparison of digital and film radiography in Dutch dental practices assessed by questionnaire.Dentomaxillofacial Radiology, 2002
- Experience of Norwegian general dental practitioners with solid state and storage phosphor detectors.Dentomaxillofacial Radiology, 2001
- Approximal Caries Depth Assessment with Storage Phosphor versus Film RadiographyCaries Research, 2000
- Reproducibility in the Assessment of Caries Lesion Behaviour: A Comparison between Conventional Film and Subtraction RadiographyCaries Research, 2000
- Prediction of Coronary Heart Disease Using Risk Factor CategoriesCirculation, 1998
- Digital radiography and caries diagnosis.Dentomaxillofacial Radiology, 1998
- Effects of digital grey-scale modification on the diagnosis of small approximal carious lesionsJournal of Dentistry, 1992
- Statistical contrast enhancement of subtraction images for radiographic caries diagnosisOral Surgery, Oral Medicine, Oral Pathology, 1982
- Notes on Technic: A Rotating Specimen Holder for Hard Tissue SectioningStain Technology, 1981
- Basic principles of ROC analysisSeminars in Nuclear Medicine, 1978