Microcatheter-assisted Trabeculotomy Versus 2-site Trabeculotomy With the Rigid Probe Trabeculotome in Primary Congenital Glaucoma
Authors:
- Yasmine M. El SayedYSYasmine M. El Sayed
- Ghada I. GawdatGGGhada I. Gawdat
- 1 April 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 27 (4) , 371-376
Abstract
Purpose: The purpose of this study was to compare the outcomes of microcatheter-assisted trabeculotomy to circumferential trabeculotomy using the rigid probe trabeculotome in primary congenital glaucoma. Methods: This retrospective study was performed in an institutional setting. The medical records of primary congenital glaucoma patients who underwent circumferential trabeculotomy (≥270 degrees incised) using Glaucolight-illuminated microcatheter or a rigid probe trabeculotome were reviewed. The primary outcomes were the percent reduction of intraocular pressure (IOP) and success rates. Complete success was defined as achieving an IOPP=0.7 and 0.3, respectively). There was no significant difference in survival time in both groups (P=0.6). Conclusion: Circumferential trabeculotomy using either the illuminated microcatheter or rigid probe trabeculotome yielded comparable results; however, the added cost of the microcatheter should be considered.Keywords
This publication has 14 references indexed in Scilit:
- Two‐year results of microcatheter‐assisted trabeculotomy in paediatric glaucoma: a randomized controlled studyActa Ophthalmologica, 2017
- Microcatheter-assisted trabeculotomy versus rigid probe trabeculotomy in childhood glaucomaBritish Journal of Ophthalmology, 2015
- Comparison of 360-degree versus traditional trabeculotomy in pediatric glaucomaJournal of American Association for Pediatric Ophthalmology and Strabismus, 2015
- Goniotomy versus circumferential trabeculotomy with an illuminated microcatheter in congenital glaucomaJournal of American Association for Pediatric Ophthalmology and Strabismus, 2012
- Subretinal Suture Misdirection During 360 Degrees Suture TrabeculotomyAmerican Journal of Ophthalmology, 2006
- Success of trabeculotomy in patients with congenital glaucoma operated on within 3 months of birthEye, 2006
- False Passage: A Complication of 360° Suture TrabeculotomyJournal of American Association for Pediatric Ophthalmology and Strabismus, 2005
- Correlation between surgical success rate and severity of congenital glaucomaBritish Journal of Ophthalmology, 2005
- Long-term surgical and visual outcomes in primary congenital glaucoma: 360° trabeculotomy versus goniotomyJournal of American Association for Pediatric Ophthalmology and Strabismus, 2000
- 360° Trabeculotomy for Primary Congenital GlaucomaArchives of Ophthalmology (1950), 1995