Effect of stereo‐EEG versus subdural EEG on functional and seizure outcome in pediatric and adult epilepsy surgery: A 21‐year single‐center experience
Open Access
- 13 May 2025
- journal article
- Published by Wiley in Epileptic Disorders
- Vol. 27 (4) , 586-599
Abstract
Objective: (1) To compare use, benefits, and complications of stereo‐EEG (SEEG) and subdural EEG (SD) in presurgical epilepsy candidates. (2) To evaluate the effectiveness of both methods in delineation of the epileptogenic zone (EZ) and guiding tailored resective surgery.Methods: We included patients with SEEG or SD evaluations in children and adults at the Bethel Epilepsy Centre, Germany, between 2000 and 2020. We retrospectively assessed epilepsy related parameters, main indication of iEEG (intracranial EEG, for identification of the EZ and functional mapping), complications, seizure, and functional outcome. The second objective was addressed by a subgroup analysis in patients with focal cortical dysplasia (FCD) and mild malformation of cortical development with oligodendroglial hyperplasia (MOGHE) for delineation of the EZ.Results: Two hundred and nineteen iEEG explorations in 215 patients (age range: 1.3–64.6 years) were assessed (SEEG, n = 78; SD, n = 141). We observed a change in iEEG usage away from SD towards SEEG. In the SEEG group, the decision rate against surgery was higher (SEEG: 23.1% vs. SE: 3.5%, p < .001) and more patients achieved seizure freedom 2 years after surgery (SEEG: 67.8% vs. SD: 46.5%, p = .008). For all iEEG, complications were rare; symptomatic intracranial bleeding only occurred in the SD group (n = 6, 4.3%). In patients with FCD/MOGHE for delineation of the EZ, all patients were operated with favorable seizure freedom after SEEG, but with acceptance of planned neurological deficits (SEEG n = 8, SD n = 20, seizure freedom rate SEEG 87.5% vs. SD 30%, p = .011; neurological deficits: SEEG n = 3 planned motor deficits vs. SD n = 1 unplanned motor deficit due to ischemia).Significance: SEEG has largely replaced SD in iEEG for the identification of the EZ. It is better tolerated and allows more freedom of choice with respect to resective surgery, resulting in the better identification of surgical candidates and delineation of the EZ with favorable seizure outcomes.Keywords
This publication has 30 references indexed in Scilit:
- Learn how to interpret and use intracranial EEG findingsEpileptic Disorders, 2024
- Extraoperative electrical stimulation mapping in epilepsy presurgical evaluation: a proposal and review of the literatureClinical Neurology and Neurosurgery, 2022
- Comparative Effectiveness of Stereotactic Electroencephalography Versus Subdural Grids in Epilepsy SurgeryAnnals of Neurology, 2021
- Stereotactic depth electrode placement surgery in paediatric and adult patients with the Neuromate robotic device: Accuracy, complications and epileptological resultsSeizure: European Journal of Epilepsy, 2021
- Analysis of Morbidity and Outcomes Associated With Use of Subdural Grids vs Stereoelectroencephalography in Patients With Intractable EpilepsyJAMA Neurology, 2019
- Increased nationwide use of stereoencephalography for intracranial epilepsy electroencephalography recordingsJournal of Clinical Neuroscience, 2018
- Treatment Outcomes in Patients With Newly Diagnosed Epilepsy Treated With Established and New Antiepileptic DrugsJAMA Neurology, 2018
- Intracranial electroencephalography with subdural and/or depth electrodes in children with epilepsy: Techniques, complications, and outcomesEpilepsy Research, 2014
- Subdural electrodesClinical Neurophysiology, 2010
- Apical temporal lobe resection; “tailored” hippocampus-sparing resection based on presurgical evaluation dataActa Neurochirurgica, 2010