Optimising tracheal intubation success rate using the Airtraq laryngoscope
Authors:
- 10 February 2009
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 64 (3) , 315-319
Abstract
Summary: In this study we have used a video‐recording, retrospective analysis technique to evaluate the influence of the Airtraq ™ laryngoscope manipulations and the resulting changes in position of the glottic opening and inter‐arytenoids cleft, on the success rate of tracheal intubation. The video recordings of the internal views of 109 tracheal intubation attempts, in 50 anaesthetised patients were analysed. We demonstrated that successful tracheal intubation using the Airtraq laryngoscope require the glottic opening to be centred in the view, and positioning the inter‐arytenoid cleft medially below the horizontal line in the centre of the view. We also demonstrated that repositioning of the Airtraq laryngoscope following a failed tracheal intubation attempt required the performance of a standard series of manoeuvres.Keywords
This publication has 10 references indexed in Scilit:
- Pentax-AWS (Airway Scope) and Airtraq: big difference between two similar devicesJournal of Anesthesia, 2008
- In-line head and neck position is preferable for tracheal intubation with the Airtraq laryngoscope compared to the sniffing positionJournal of Anesthesia, 2008
- A comparison of cervical spine movement during laryngoscopy using the Airtraq ® or Macintosh laryngoscopes*Anaesthesia, 2008
- Tracheal intubation of morbidly obese patients: a randomized trial comparing performance of Macintosh and Airtraq™ laryngoscopesBritish Journal of Anaesthesia, 2008
- Evaluation of the Airtraq ® and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation*Anaesthesia, 2008
- Airtraq vs standard laryngoscopy by student paramedics and experienced prehospital laryngoscopists managing a model of difficult intubation*Anaesthesia, 2007
- Use of the Airtraq laryngoscope in a model of difficult intubation by prehospital providers not previously trained in laryngoscopyAnaesthesia, 2007
- The Management of Difficult Direct Laryngoscopy and Intubation in a Field Hospital: An Alternative to Fibreoptic EndoscopyJournal of the Royal Army Medical Corps, 2007
- A comparison of two techniques for inserting the Airtraq ™ laryngoscope in morbidly obese patientsAnaesthesia, 2007
- Evaluation of intubation using the Airtraq ® or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy – a manikin study*Anaesthesia, 2006