OUTCOMES OF SULFUR HEXAFLUORIDE (SF6) VERSUS PERFLUOROPROPANE (C3F8) GAS TAMPONADE FOR MACULAR HOLE SURGERY
Authors:
- Sung Soo KimSKSung Soo Kim
- William E. SmiddyWSWilliam E. Smiddy
- William J. FeuerWFWilliam J. Feuer
- Wei ShiWSWei Shi
- 1 November 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Retina
- Vol. 28 (10) , 1408-1415
Abstract
To compare outcomes of macular hole surgery using sulfur hexafluoride (SF6) gas versus perfluoropropane (C3F8) gas for idiopathic macular hole repair. Retrospective, interventional, comparative cohort study. Institutional clinical practice. A consecutive group of patients undergoing macular hole surgery with SF6 group (38 eyes of 38 patients) and a nonconsecutive, contemporaneous, comparison group with C3F8 was used (41 eyes of 39 patients). Vitrectomy for macular hole surgery using either of two different gases for internal tamponade. Best corrected logarithm of minimal angle resolution visual acuity, anatomic closure, reoperations, development of cataract, and complications such as retinal detachment. The macular hole closure rate was similar in both groups [34/38 (90%) with SF6 gas versus 37/41 (91%) with C3F8 gas, P = 0.91]. At 6 months after macular hole surgery, best-corrected visual acuity was improved compare with baseline visual acuity by a mean of 0.32 logarithm of minimal angle resolution in the SF6 group (P = 0.045) and 0.52 logarithm of minimal angle resolution in the C3F8 group (P < 0.001). Development of vision-impairing cataract in phakic eyes was not different, but the myopic shift was greater in the C3F8 group (P = 0.016). Macular hole surgery using SF6 gas yields similar results as with C3F8 gas and may be a good option.Keywords
This publication has 29 references indexed in Scilit:
- Functional outcome and patient preferences following combined phaco-vitrectomy for macular hole without prone posturingEye, 2007
- Macular hole surgery without prone positioningEye, 2006
- Macular hole surgery with internal limiting membrane removal, air tamponade, and 1-day prone positioningJapanese Journal of Ophthalmology, 2003
- Visual and anatomical success with short-term macular tamponade and autologous platelet concentrateGraefe's Archive for Clinical and Experimental Ophthalmology, 2000
- Surgery for full- thickness macular holes with short-duration prone posturing: Results of a pilot studyEye, 2000
- Macular hole surgery with internal-limiting membrane peeling and intravitreous airOphthalmology, 1999
- MACULAR HOLE SURGERY WITHOUT FACE-DOWN POSITIONINGRetina, 1997
- INTRAOCULAR TAMPONADE DURATION AND SUCCESS OF MACULAR HOLE SURGERYRetina, 1996
- Vitreous Surgery for Macular HolesOphthalmology, 1993
- Vitreous Surgery for Idiopathic Macular HolesArchives of Ophthalmology (1950), 1991