Visian Toric Implantable Collamer Lens for Correction of Compound Myopic Astigmatism
Authors:
- Daniel EliesDEDaniel Elies
- Tirso AlonsoTATirso Alonso
- Javier PuigJPJavier Puig
- Oscar GrisOGOscar Gris
- José Luís GüellJGJosé Luís Güell
- Andreu CoretACAndreu Coret
- 1 April 2010
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 26 (4) , 251-258
Abstract
PURPOSE: To assess the safety, efficacy, predictability, and stability of a toric posterior chamber phakic intraocular lens for the correction of myopia with astigmatism. METHODS: A non-randomized, retrospective analysis of 63 eyes of 36 patients with a minimum follow-up of 6 months was performed. The STAAR Toric Implantable Collamer Lens (TICL) was implanted under topical anesthesia through a 3-mm temporal clear corneal incision. Mean preoperative spherical equivalent refraction was −10.71±3.55 diopters (D). Median preoperative best spectacle-corrected visual acuity (BSCVA) was 20/25, with a mean sphere of −8.78 D (range: −2.50 to −16.50 D) and mean cylinder of 3.60 D (range: 1.25 to 7.00 D). Postoperative parameters were analyzed at different time points, and vector analysis was performed to calculate surgically induced astigmatism. RESULTS: Fifty-nine (93.6%) eyes had a spherical equivalent refraction within ±1.00 D and 52 (82.5%) eyes were within ±0.50 D of emmetropia. Median postoperative uncorrected visual acuity was 20/25 and BSCVA was 20/20. Preoperative keratometric astigmatism was 1.99@178.2 vs 1.82@178.6 postoperative kerato-metric astigmatism, most likely due to the surgical incision. Preoperative refractive astigmatism was 2.17@93 whereas postoperatively it reduced to 0.38@99.6. No eye lost 2 or more lines of Snellen BSCVA. Twenty-two (34.9%) eyes gained 2 or more Snellen lines of vision. Preoperatively, 45 (71.4%) eyes had a BSCVA of 20/30 or better, whereas 60 (95.2%) eyes were within this range of BSCVA after surgery. The TICL demonstrated good rotational stability in this study. CONCLUSIONS: Implantation of the STAAR TICL was an effective, predictable, and safe method for correction of high myopia and myopic astigmatism as shown in this retrospective observational series. [ J Refract Surg . 2010;26:251–258.]Keywords
This publication has 26 references indexed in Scilit:
- Meridional differences in internal dimensions of the anterior segment in human eyes evaluated with 2 imaging systemsJournal of Cataract & Refractive Surgery, 2008
- Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurementsJournal of Cataract & Refractive Surgery, 2008
- Evaluation of the relationship between corneal diameter and lens diameterJournal of Cataract & Refractive Surgery, 2008
- Corneal diameter measurements by corneal topography and angle-to-angle measurements by optical coherence tomography: Evaluation of equivalenceJournal of Cataract & Refractive Surgery, 2008
- Magnetic resonance imaging and Orbscan assessment of the anterior chamberJournal of Cataract & Refractive Surgery, 2005
- Traumatic cataract and other adverse events with the implantable contact lensJournal of Cataract & Refractive Surgery, 2005
- Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyesJournal of Cataract & Refractive Surgery, 2004
- Phakic intraocular lenses to correct high myopiaJournal of Cataract & Refractive Surgery, 2004
- U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopiaOphthalmology, 2003
- Toric phakic intraocular lensOphthalmology, 2003