β-Trace Protein in Serum: A New Marker of Glomerular Filtration Rate in the Creatinine-Blind Range
Authors:
Open Access
- 1 April 1999
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 45 (4) , 567-568
Abstract
Recent studies have shown that low-molecular weight proteins in serum seem to be better markers for detecting reduced glomerular filtration rate (GFR) than the conventional measurement of serum creatinine (1)(2). Several proteins, such as ribonuclease, α1-microglobulin, β2-microglobulin (B2M), and cystatin C have been compared with serum creatinine (2)(3). Whereas serum creatinine is increased only after a reduction of ∼50% in GFR, the above proteins, especially cystatin C, are already increased within that so-called creatinine-blind range (1)(4)(5)(6). Recently, another low-molecular weight protein, the β-trace protein (BTP), isolated primarily from cerebrospinal fluid (7), was shown to be increased in patients with renal diseases (8)(9). However, there is no information on the relationship of BTP and a standard measure of GFR such as inulin clearance. Therefore, to investigate the potential clinical usefulness of BTP for early detection of reduced GFR, we have performed corresponding measurements of BTP and inulin clearance.Keywords
This publication has 10 references indexed in Scilit:
- The Search Continues—An Ideal Marker of GFRClinical Chemistry, 1997
- Initial evaluation of cystatin C measurement by particle-enhanced immunonephelometry on the Behring nephelometer systems (BNA, BN II)Clinical Chemistry, 1997
- Molecular characterization of β-trace protein in human serum and urine: a potential diagnostic marker for renal diseasesGlycobiology, 1997
- Reference intervals for the glomerular filtration rate and cell-proliferation markers: serum cystatin C and serum β2-microglobulin/cystatin C-ratioScandinavian Journal of Clinical and Laboratory Investigation, 1997
- Serum cystatin C measured by automated immunoassay: A more sensitive marker of changes in GFR than serum creatinineKidney International, 1995
- Software for illustrative presentation of basic clinical characteristics of laboratory tests - GraphROC for WindowsScandinavian Journal of Clinical and Laboratory Investigation, 1995
- Serum cystatin C, determined by a rapid, automated particle-enhanced turbidimetric method, is a better marker than serum creatinine for glomerular filtration rateClinical Chemistry, 1994
- Sandwich enzyme immunoassay of cystatin C in serum with commercially available antibodiesClinical Chemistry, 1993
- Fully Enzymatic Inulin Determination in Small Volume Samples without DeproteinizationNephron, 1992
- Proteins in Normal Cerebrospinal Fluid Not Found in Serum.Experimental Biology and Medicine, 1961