Optimum Two-Dimensional Uniform Spatial Sampling for Microwave SAR-Based NDE Imaging Systems
- 17 October 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 60 (12) , 3806-3815
Abstract
Microwave imaging systems for nondestructive evaluation, based on 3-D synthetic aperture radar (SAR) techniques, utilize either a real aperture, composed of many antennas mounted next to one another, or a synthetic aperture, generated by raster scanning a single antenna. To obtain a quality SAR image, the spatial sampling must be dense enough to accurately sample the electric field reflected from a target. Conversely, the quantity of spatial samples may be optimally reduced, resulting in reduced system complexity and required resources for systems employing real apertures and reduced imaging time for synthetic aperture systems. In the literature, it has been reported that the optimum sampling step size is equal to the theoretical resolution, as per the Nyquist rate. It has also been reported that an image generated using a sampling step size equal to the theoretical resolution may not possess the same spatial resolution as predicted. Also, as expected and reported, resolution is dependent upon the distance between the target and the aperture, aperture dimensions, and antenna beamwidth. However, existing formulations of SAR resolution do not account for all of the physical characteristics of a measurement (e.g., 2-D limited-size aperture, electric field decreasing with distance from the measuring antenna, etc.). This paper presents a theoretical formulation of resolution and a study into optimum uniform spatial sampling by analyzing simulated 3-D SAR images according to metrics representing image quality, namely, half-power resolution and RMS error between practically sampled images and an ideally sampled image. The results of this simulation demonstrate optimum sampling given design requirements that fully explain resolution dependence on sampling step size. Also, it is found that there is additional widening of the 2-D spectral estimation of the data due to the aperture-limited nature of the measurements, which further influences the choice of sampling step size. Subsequently, the simulated results are compared to experimental results corroborating the efficacy of the formulation. Finally, design curves and procedures are proposed for selecting sampling step size as per resolution requirements.Keywords
This publication has 10 references indexed in Scilit:
- Portable Real-Time Microwave Camera at 24 GHzIEEE Transactions on Antennas and Propagation, 2011
- Using NFFT 3---A Software Library for Various Nonequispaced Fast Fourier TransformsACM Transactions on Mathematical Software, 2009
- Millimeter-Wave Detection of Localized Anomalies in the Space Shuttle External Fuel Tank Insulating FoamIEEE Transactions on Instrumentation and Measurement, 2006
- An approach to SAR imaging by means of non-uniform FFTs2004
- A comparison of non-parametric spectral estimators for SAR imaging2003
- Three-dimensional millimeter-wave imaging for concealed weapon detectionIEEE Transactions on Microwave Theory and Techniques, 2001
- 3-D radar imaging using range migration techniquesIEEE Transactions on Antennas and Propagation, 2000
- Fast Fourier Transforms for Nonequispaced DataSIAM Journal on Scientific Computing, 1993
- A system model and inversion for synthetic aperture radar imagingIEEE Transactions on Image Processing, 1992
- Bistatic synthetic aperture radar inversion with application in dynamic object imagingIEEE Transactions on Signal Processing, 1991