Abstract
Two simple, specific, sensitive, accurate and precise stability indicating methods were described for quantitative determination of the anthelmintics drug Niclosamide. The first method was high performance liquid chromatographic with the use of a reversed phase hibarR C-18 column (250mm×4.66mm, 5μm) and mobile phase of methanol: 1mM ammonium phosphate buffer (85:15 v/v) at a flow rate of 1.2mL/min. The retention time of drug was found to be 6.45±0.02min. Quantification of drug was achieved with diode array detection (DAD) at 332nm. Linear calibration curve was obtained in concentration range 0.01–100μg/mL with r2 value of 0.999. The limit of detection and limit of quantification were found to be 0.048μg/mL and 0.01μg/ml respectively. The second method involved a high performance thin layer liquid chromatographic. Chromatographic separation was carried out with precoated silica gel G60 F254 aluminum sheets using toluene:ethyl acetate (7:3% v/v) as a mobile phase. Linearity of proposed method was found to be 200–700ng/band at 332nm with retention factor of 0.59 and r2 value of 0.998. The limit of detection and limit of quantification were found to be 36.21ng/band and 109.7ng/band respectively. Both the developed methods were successfully validated as per International Conference on Harmonization guideline (ICH). Niclosamide was subjected to different stress conditions. The degraded product peaks were well resolved from the pure drug peak with significant difference in their retention time. Stress samples were successfully assayed by developed high performance liquid chromatographic and high performance thin layer liquid chromatographic method. Statistically analysis proves that there were no statistical significant differences between two developed methodsKeywords
This publication has 12 references indexed in Scilit:
- Development and validation of a new RP-HPLC method for determination of quercetin in green teaJournal of Analytical Chemistry, 2013
- Niclosamide quantification in methyl-β-cyclodextrin after derivatization to aminoniclosamideJournal of Inclusion Phenomena and Macrocyclic Chemistry, 2011
- Multi-residue determination of phenolic and salicylanilide anthelmintics and related compounds in bovine kidney by liquid chromatography–tandem mass spectrometryJournal of Chromatography A, 2009
- Simultaneous HPLC Determination of Levamisole Hydrochloride and Anhydrous Niclosamide in Veterinary Powders, and its ValidationJournal of Liquid Chromatography & Related Technologies, 2007
- Electrochemical oxidation of niclosamide at a glassy carbon electrode and its determination by voltammetryBulletin of the Chemical Society of Ethiopia, 2003
- Detection of the damage caused to DNA by niclosamide using an electrochemical DNA-biosensorBiosensors and Bioelectronics, 2002
- Selective Differential Spectrophotometric Methods for Determination of Niclosamide and Drotaverine HydrochlorideAnalytical Letters, 2000
- Spectrophotometric Determination of Niclosamide and Thiabendazole in TabletsAnalytical Letters, 1994
- Extractive alkylation of 5,2′-dichloro-4′-nitrosalicylanilide (niclosamide) for gas-liquid chromatographic analysisJournal of Chromatography A, 1980