Abstract
Outdoor evaluation of passive daytime radiative cooling (PDRC) materials is highly sensitive to experimental boundary conditions, yet the influence of testing methodologies on reported cooling performance remains poorly understood. Here, we identify and analyze the key environmental and experimental factors that impact PDRC thermal characterization through a combination of critical literature analysis, targeted outdoor experiments, and numerical simulations. We then quantitatively demonstrate that sample enclosure architecture systematically biases measured cooling performance. Simultaneous measurements of a benchmark PDRC material in representative enclosure geometries reveal peak differences in apparent daytime sub-ambient cooling approaching 2 ºC despite identical environmental conditions. These results show that reported cooling metrics often reflect coupled sample-enclosure behavior rather than intrinsic material performance. Finally, practical guidelines for enclosure design and experimental reporting are provided, together with a reference test configuration that enables more accurate, reproducible, and comparable outdoor characterization of PDRC materials.