Improving Cup Positioning Using a Mechanical Navigation Instrument
Open Access
- 1 February 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (2) , 423-428
Abstract
Although surgical navigation reduces the rate of malpositioned acetabular cups in total hip arthroplasty (THA), its use has not been widely adopted. As a result of our perceived need for simple and efficient methods of navigation, we developed a mechanical navigation device for acetabular cup orientation. We assessed accuracy of cup orientation (mean error of cup inclination and anteversion) of a novel mechanical navigation device, percentage of outliers, length of operation, and compared the results with a series of CT-based computer-assisted THAs. Cup orientation of 70 THAs performed using the mechanical navigation device was compared with a historical control group of 146 THAs performed using CT-based computer navigation. Postoperative cup orientation was measured using a validated two-dimensional/three-dimensional matching method. An outlier was defined outside a range of ± 10° from the planned inclination and/or anteversion. Using the mechanical navigation device, we observed a decrease in the errors of inclination (1.3° ± 3.4° [range, −6.6° to 8.2°] versus 3.5° ± 4.2° [−12.7° to 6.9°]), errors of anteversion (1.0° ± 4.1° [−8.8° to 9.5°] versus 3.0° ± 5.8° [−11.8° to 19.6°]), percentages of outliers (0% versus 9.6%), and length of operation (112 ± 22 [78–184] minutes versus 132 ± 18 [90–197] minutes) compared with CT-based navigation. Compared with CT-based surgical navigation, navigation of acetabular cup orientation using a mechanical device can be performed in less time, lower mean errors, and minimal equipment.Keywords
This publication has 28 references indexed in Scilit:
- Validation of a new method for determination of cup orientation in THAJournal of Orthopaedic Research, 2009
- The 2008 Frank Stinchfield Award: Variation in Postoperative Pelvic Tilt May Confound the Accuracy of Hip Navigation SystemsClinical Orthopaedics and Related Research, 2009
- Pseudotumours associated with metal-on-metal hip resurfacingsThe Journal of Bone and Joint Surgery. British volume, 2008
- Containment versus impingement: finding a compromise for cup placement in total hip arthroplastyInternational Orthopaedics, 2007
- Two- to 9-Year Clinical Results of Alumina Ceramic-on-Ceramic THAClinical Orthopaedics and Related Research, 2006
- Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matchingComputer Aided Surgery, 2005
- Pfannenplatzierung in der Hüftendoprothetik - vergleichende Untersuchung freihand implantierter und computerassistiert platzierter Hüftpfannen - eine MultizenterstudieZeitschrift für Orthopädie und ihre Grenzgebiete, 2004
- Measurements of Pelvic Flexion Angle Using Three-Dimensional Computed TomographyClinical Orthopaedics and Related Research, 2003
- Reduction in variability of acetabular cup abduction using computer assisted surgery: A prospective and randomized studyComputer Aided Surgery, 2002
- Reduction in Variability of Acetabular Cup Abduction Using Computer Assisted Surgery: A Prospective and Randomized StudyComputer Aided Surgery, 2002