Enhanced Metabolome Coverage and Evaluation of Matrix Effects by the Use of Experimental-Condition-Matched 13C-Labeled Biological Samples in Isotope-Assisted LC-HRMS Metabolomics
Open Access
- 27 October 2020
- journal article
- research article
- Published by MDPI AG in Metabolites
- Vol. 10 (11) , 434
Abstract
Stable isotope-assisted approaches can improve untargeted liquid chromatography-high resolution mass spectrometry (LC-HRMS) metabolomics studies. Here, we demonstrate at the example of chemically stressed wheat that metabolome-wide internal standardization by globally 13C-labeled metabolite extract (GLMe-IS) of experimental-condition-matched biological samples can help to improve the detection of treatment-relevant metabolites and can aid in the post-acquisition assessment of putative matrix effects in samples obtained upon different treatments. For this, native extracts of toxin- and mock-treated (control) wheat ears were standardized by the addition of uniformly 13C-labeled wheat ear extracts that were cultivated under similar experimental conditions (toxin-treatment and control) and measured with LC-HRMS. The results show that 996 wheat-derived metabolites were detected with the non-condition-matched 13C-labeled metabolite extract, while another 68 were only covered by the experimental-condition-matched GLMe-IS. Additional testing is performed with the assumption that GLMe-IS enables compensation for matrix effects. Although on average no severe matrix differences between both experimental conditions were found, individual metabolites may be affected as is demonstrated by wrong decisions with respect to the classification of significantly altered metabolites. When GLMe-IS was applied to compensate for matrix effects, 272 metabolites showed significantly altered levels between treated and control samples, 42 of which would not have been classified as such without GLMe-IS.Keywords
Funding Information
- Austrian Science Fund (F3715 and F3711)
This publication has 51 references indexed in Scilit:
- New Untargeted Metabolic Profiling Combining Mass Spectrometry and Isotopic Labeling: Application on Aspergillus fumigatus Grown on WheatAnalytical Chemistry, 2013
- Addressing The Current Bottlenecks of Metabolomics: Isotopic Ratio Outlier Analysis™, An Isotopic-Labeling Technique For Accurate Biochemical ProfilingBioanalysis, 2012
- Nonlinear Signal Response in Electrospray Mass Spectrometry: Implications for Quantitation of Arsenobetaine Using Stable Isotope Labeling by Liquid Chromatography and Electrospray Orbitrap Mass SpectrometryAnalytical Chemistry, 2012
- Exploring Matrix Effects and Quantification Performance in Metabolomics Experiments Using Artificial Biological GradientsAnalytical Chemistry, 2011
- Characterization of Differences between Blood Sample Matrices in Untargeted MetabolomicsAnalytical Chemistry, 2010
- Identifying, Evaluating, and Controlling Bioanalytical Risks Resulting from Nonuniform Matrix Ion Suppression/Enhancement and Nonlinear Liquid Chromatography−Mass Spectrometry Assay ResponseAnalytical Chemistry, 2010
- ProteoWizard: open source software for rapid proteomics tools developmentBioinformatics, 2008
- Does a stable isotopically labeled internal standard always correct analyte response?Journal of Pharmaceutical and Biomedical Analysis, 2007
- MIRACLE: mass isotopomer ratio analysis of U‐13C‐labeled extracts. A new method for accurate quantification of changes in concentrations of intracellular metabolitesBiotechnology and Bioengineering, 2004
- Practical implications of some recent studies in electrospray ionization fundamentalsMass Spectrometry Reviews, 2001