A PDMS-Based 2-Axis Waterproof Scanner for Photoacoustic Microscopy
Open Access
Abstract
Optical-resolution photoacoustic microscopy (OR-PAM) is an imaging tool to provide in vivo optically sensitive images in biomedical research. To achieve a small size, fast imaging speed, wide scan range, and high signal-to-noise ratios (SNRs) in a water environment, we introduce a polydimethylsiloxane (PDMS)-based 2-axis scanner for a flexible and waterproof structure. The design, theoretical background, fabrication process and performance of the scanner are explained in details. The designed and fabricated scanner has dimensions of 15 × 15 × 15 mm along the X, Y and Z axes, respectively. The characteristics of the scanner are tested under DC and AC conditions. By pairing with electromagnetic forces, the maximum scanning angles in air and water are 18° and 13° along the X and Y axes, respectively. The measured resonance frequencies in air and water are 60 and 45 Hz along the X axis and 45 and 30 Hz along the Y axis, respectively. Finally, OR-PAM with high SNRs is demonstrated using the fabricated scanner, and the PA images of micro-patterned samples and microvasculatures of a mouse ear are successfully obtained with high-resolution and wide-field of view. OR-PAM equipped with the 2-axis PDMS based waterproof scanner has lateral and axial resolutions of 3.6 μm and 26 μm, respectively. This compact OR-PAM system could potentially and widely be used in preclinical and clinical applications.Keywords
Funding Information
- NIPA IT Consilience Creative Program (NIPA-2013-H0203-13-1001)
- NRF Engineering Research Center grant (NRF-2011-0030075)
- NRF Mid-career Researcher Program (NRF-2012R1A2A2A06047424)
This publication has 27 references indexed in Scilit:
- Investigation of Neovascularization in Three-Dimensional Porous Scaffolds In Vivo by a Combination of Multiscale Photoacoustic Microscopy and Optical Coherence TomographyTissue Engineering Part C: Methods, 2013
- Photoacoustic microscopyLaser & Photonics Reviews, 2013
- A water-immersible 2-axis scanning mirror microsystem for ultrasound andha photoacoustic microscopic imaging applicationsMicrosystem Technologies, 2012
- Wide-field fast-scanning photoacoustic microscopy based on a water-immersible MEMS scanning mirrorJournal of Biomedical Optics, 2012
- Fiber-laser-based photoacoustic microscopy and melanoma cell detectionJournal of Biomedical Optics, 2011
- In Vivo Photoacoustic Tomography of Chemicals: High-Resolution Functional and Molecular Optical Imaging at New DepthsChemical Reviews, 2010
- Photoacoustic ophthalmoscopy for in vivo retinal imagingOptics Express, 2010
- Neurovascular photoacoustic tomographyFrontiers in Neuroenergetics, 2010
- The mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applicationsJournal of Micromechanics and Microengineering, 1997
- Polydimethylsiloxane as an elastic material applied in a capacitive accelerometerJournal of Micromechanics and Microengineering, 1996