The microstructure of 33 spontaneously degenerated porcine bioprosthetic valves was assessed by scanning electron microscopy in order to gather insight regarding the degenerative process. Twenty-four mitral and 9 aortic valves were removed from 32 patients. The duration of insertion was 7.7 +/- 2.4 years (mean +/- SD). All valves showed denudation of endothelial cells and exposure of the subendothelial fibrous tissue. Fibroblastlike cells were occasionally seen. Platelet deposits were observed on 22 of 33 valves (67%). Leukocytes were observed on the surface of 27 of 33 valves (82%). Mononuclear leukocytes were the most common category of cells (66%). Crystalline material was present on the surface of some leukocytes, suggesting that they may serve as a nidus for calcification. Transmission electron microscopy showed leukocytes in the process of phagocytizing collagen fibers. Macrophages, by exerting their scavenger function seem to contribute to destruction of the collagen framework of the valves. Whether the observed lymphocytes and plasma cells reflect an immunological involvement is unclear.Keywords
This publication has 16 references indexed in Scilit:
- Antithrombotic Therapy in Mechanical and Biological Prosthetic Heart Valves and Saphenous Vein Bypass GraftsChest, 1986
- Finite element evaluation of stresses on closed leaflets of bioprosthetic heart valves with flexible stentsFinite Elements in Analysis and Design, 1985
- Estimation of mechanical stresses on closed cusps of porcine bioprosthetic valves: Effects of stiffening, focal calcium and focal thinningThe American Journal of Cardiology, 1985
- Occurrence and significance of endothelial cells in implanted porcine bioprosthetic valvesThe American Journal of Cardiology, 1981
- Platelet reactivity in patients with degenerated porcine bioprosthetic valvesThrombosis Research, 1981
- Structural changes in glutaraldehyde-treated porcine heterografts used as substitute cardiac valvesThe American Journal of Cardiology, 1978
- Structural changes in porcine xenografts used as substitute cardiac valvesThe American Journal of Cardiology, 1977
- Porcine Aortic Valves as Replacements for Human Heart ValvesThe Annals of Thoracic Surgery, 1974
- AN IMPROVED STAINING METHOD FOR ELECTRON MICROSCOPYJournal of Cell Biology, 1964
- THE USE OF LEAD CITRATE AT HIGH pH AS AN ELECTRON-OPAQUE STAIN IN ELECTRON MICROSCOPYJournal of Cell Biology, 1963