Clinical Evaluation of a Novel System for Monitoring Surgical Hemoglobin Loss
Authors:
- Allen A. HolmesAHAllen A. Holmes
- Gerhardt KonigGKGerhardt Konig
- Vicki TingVTVicki Ting
- Bridget PhilipBPBridget Philip
- Thomas PuzioTPThomas Puzio
- Siddarth SatishSSSiddarth Satish
- Jonathan H. WatersJWJonathan H. Waters
- 1 September 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 119 (3) , 588-594
Abstract
Ogrammed with a unique algorithm modeled after facial recognition technology. In this study, we assessed the accuracy and performance of the system in surgical cases. METHODS: In this prospective, multicenter study, 46 patients undergoing surgery with anticipated significant blood loss contributed laparotomy sponges for hemoglobin (Hb) loss measurement using the Triton System with Feature Extraction Technology (Gauss Surgical, Inc., Los Altos, CA). The Hb loss measured by the new system was compared with that measured by manual rinsing of the sponges. Accuracy was evaluated using linear regression and Bland-Altman analysis. In addition, the new system’s calculation of blood volume loss was compared with the gravimetric method of estimating blood loss from intraoperative sponge weights. RESULTS: A significant positive linear correlation was noted between the new system’s measurements and the rinsed Hb mass (r = 0.93, P < 0.0001). Bland-Altman analysis revealed a bias of 9.0 g and narrow limits of agreement (−7.5 to 25.5 g) between the new system’s measures and the rinsed Hb mass. These limits were within the clinically relevant difference of ±30 g, which is approximately half of the Hb content of a unit of allogeneic whole blood. Bland-Altman analysis of the estimated blood loss on sponges using the gravimetric method demonstrated a bias of 466 mL (overestimation) with limits of agreement of −171 and 1103 mL, due to the presence of contaminants other than blood on the laparotomy sponges. CONCLUSIONS: The novel mobile monitoring system provides an accurate measurement of Hb mass on surgical sponges as compared with that of manual rinsing measurements and is significantly more accurate than the gravimetric method. Further study is warranted to assess the clinical use of the technology....Keywords
This publication has 21 references indexed in Scilit:
- Reducing Noninfectious Risks of Blood TransfusionAnesthesiology, 2011
- Validation of a rapid alkaline hematin technique to measure menstrual blood loss on feminine towels containing superabsorbent polymersFertility and Sterility, 2011
- Measurement of Blood Loss: Review of the LiteratureJournal of Midwifery & Women's Health, 2010
- Visually estimated and calculated blood loss in vaginal and cesarean deliveryAmerican Journal of Obstetrics and Gynecology, 2008
- Postoperative blood loss and transfusion associated with use of Hextend in cardiac surgery patients at a blood conservation centerTransfusion, 2008
- Estimating Blood Loss: Can Teaching Significantly Improve Visual Estimation?Obstetrics & Gynecology, 2004
- Estimated Blood Loss Underestimates Calculated Blood Loss during Radical Retropubic ProstatectomyUrologia Internationalis, 2004
- The estimation of blood loss during burns surgeryBurns, 1993
- Assessing Gravimetric Estimation of Intraoperative Blood LossJournal of Gynecologic Surgery, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986