The Role of the Independent Variable to Glucose Sensor Calibration
Authors:
- 1 June 2003
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 5 (3) , 401-410
Abstract
In vivo subcutaneous glucose sensor accuracy depends on the calibration method. Sensor accuracy was assessed during standard oral glucose tolerance tests in six non-diabetic subjects each wearing six subcutaneous glucose sensors (Medtronic MiniMed). Paired blood glucose (BG) and sensor current readings were used for retrospective sensor calibration using either BG or sensor current as the independent variable. Sensor accuracy after calibration was assessed using three criteria: linear regression between BG and sensor glucose (SG); correlation; and mean absolute difference (MAD), defined as 100 × |BG - SG|/BG. Calibration with BG as the independent variable resulted in unbiased estimates of regression slope (1.02, not different than 1, p< 0.01) and y-intercept (-1.06 mg/dL, not different than 0, p< 0.01). In contrast, calibration with sensor current as the independent variable resulted in biased estimates of slope (0.76, different than 1, p< 0.01) and y-intercept (31.25 mg/dL, different than 0, p< 0.01). However, with sensor current as the independent variable, the MAD was lower than the corresponding value for calibration with BG at the x-axis (15.00 ± 0.47% vs. 18.35 ± 0.63%, p< 0.01). The Pearson correlation coefficient between BG and SG was higher when using sensor current as the independent variable (R = 0.82 vs. R = 0.79 when using glucose on the x-axis). We suggest that despite the fact that calibration with sensor current as the independent variable leads to a bias in the estimate of BG, it is a more appropriate calibration method when the primary concern is minimization of the MAD between SG and BG.Keywords
This publication has 19 references indexed in Scilit:
- Do Sensor Glucose Levels Accurately Predict Plasma Glucose Concentrations During Hypoglycemia and Hyperinsulinemia?Diabetes Care, 2002
- Use of a Subcutaneous Glucose Sensor To Detect Decreases in Glucose Concentration Prior to Observation in BloodAnalytical Chemistry, 1996
- A Comprehensive Assessment of the Avoidability of Long-Term Complications of Diabetes. A case-control study. SID-AMD Italian Study Group for the Implementation of the St. Vincent DeclarationDiabetes Care, 1996
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusThe New England journal of medicine, 1993
- The Effect of Long-Term Intensified Insulin Treatment on the Development of Microvascular Complications of Diabetes MellitusNew England Journal of Medicine, 1993
- Meta-analysis of effects of intensive blood-glucose control on late complications of type I diabetes*1The Lancet, 1993
- On Line Continuous Monitoring of Subcutaneous Tissue Glucose is Feasible by Combining Portable Glucosensor with MicrodialysisHormone and Metabolic Research, 1993
- Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoringAnalytical Chemistry, 1991
- A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurementComputers in Biology and Medicine, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986