An evaluation of the performance of the Point of Care Test iCHROMA™ AFP method: Precision and accuracy
Authors:
Open Access
- 23 December 2021
- journal article
- research article
- Published by Journal of Global Medicine, Ibadan Medical Specialist Group in Journal of Global Medicine
- Vol. 1 (2) , e7
Abstract
The estimation of serum alpha-fetoprotein (AFP) is useful in the diagnosis and monitoring of primary hepatocellular carcinoma, hepatoblastoma, non-seminomatous testicular germ cell tumours and other germ cell tumours. The iCHROMA™ AFP is a lateral flow chromatography, fluorescence immunoassay (FIA) for the quantitative determination of AFP in serum or plasma. In this study, the Boditech iCHROMA™ AFP assay had a very good precision of 9.8%. It showed a very good correlation with the following 12 methods: Abbott Architect (r2 = 0.9705), BioMerieux VIDAS (r2 = 0.9717), Roche Cobas 6000/8000 (r2 = 0.9738), Siemens Centaur XP/XPT/Classic (r2 = 0.9654), Siemens/DPC/Immulite 2000/2500 (r2 = 0.9673), Siemens/DPC/Immulite 1000 (r2 = 0.9670), Beckman Dxl 600/800 (r2 = 0.9676), Roche Elecsys (r2 = 0.9683), Roche Cobas 4000/e411 (r2 = 0.9688), Roche Modular E170 (r2 = 0.9692), SNIBE Maglumi (r2 = 0.9457) and Ortho Vitros 3600/5600/ECi (r2 = 0.9714). In summary, the iCHROMA™ AFP, a rapid point of care test method, has a within-run precision value of less than 10% and excellent correlations with traditional laboratory methods. There is a consistent overestimation with the iCHROMA™ method, which must be taken into consideration when setting a reference range.Keywords
This publication has 6 references indexed in Scilit:
- Biology and significance of alpha‐fetoprotein in hepatocellular carcinomaLiver International, 2019
- An Evaluation of the Novel i-CHROMA™ Point-of-Care Testing (POCT) Method for the Analysis of Prostate-Specific Antigen (PSA) in SerumBiomedical Journal of Scientific & Technical Research, 2018
- An Assessment of Automated Vitamin D Measurement Methods Including a Point-of-Care Testing Method, I-CHROMA™ Using the Randox International Quality Assurance Scheme (Riqas)Biomedical Journal of Scientific & Technical Research, 2018
- An Evaluation of the Point-of-Care Test i-CHROMA Prostate-Specific Antigen Method for Screening in the CommunityPoint of Care: The Journal of Near-Patient Testing & Technology, 2017
- Comparison of the point of care test (POCT), i-CHROMA™ human chorionic gonadotrophin (HCG), leutinzing hormone (LH) and follicle stimulating hormone (FSH) methods with the other laboratory methods in the Randox International Quality Assessment Scheme (RIQAS)Clinical Obstetrics, Gynecology and Reproductive Medicine, 2017
- A Rapid Quantitative Determination Method of AFP Concentration with Gold Immunochromatographic StripJournal of Computers, 2012