Evaluation of Type 3 Portable Monitoring in Unattended Home Setting for Suspected Sleep Apnea: Factors That May Affect its Accuracy
Authors:
- 1 February 2006
- journal article
- research article
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 134 (2) , 204-209
Abstract
OBJECTIVE: This study evaluates the reliability of type 3 portable monitoring (PM) in a home setting.STUDY DESIGN AND SETTING: Prospective study in sleep laboratory. Type 3 device (Stardust II) was evaluated in comparison with standard polysomnography (PSG) among patients with obstructive sleep apnea. Quality of recorded data and agreement between PM and PSG results were evaluated.RESULTS: Low quality of recorded data was observed only in 5 cases. Pattern of disordered breathing was recognized correctly by PM. Apnea/hypopnea index (AHI) correlated well with a mean bias of 3.7 ± 13.1/h. High sensitivity of PM was observed generally, whereas specificity was lower in mild patients. AHI, record time, and sleep position were found to be the main factors that would affect the accuracy of PM.CONCLUSION: Type 3 PM is feasible in unattended home‐setting for routine examination. Influence of the factors above should be comprehensively considered especially for mild patients.Keywords
This publication has 19 references indexed in Scilit:
- A preliminary study on application of portable monitoring for diagnosis of obstructive sleep apneaAuris Nasus Larynx, 2005
- First night effect in children and adolescents undergoing polysomnography for sleep-disordered breathingClinical Neurophysiology, 2003
- Scoring polysomnography respiratory events: the utility of nasal pressure and oro-nasal thermal sensor recordingsSleep Medicine, 2003
- Comparison of the NovaSom QSG™, a new sleep apnea home-diagnostic system, and polysomnographySleep Medicine, 2003
- Evaluation of a Portable Device Based on Peripheral Arterial Tone for Unattended Home Sleep StudiesaChest, 2003
- Scoring variability between polysomnography technologists in different sleep laboratoriesSleep Medicine, 2002
- The first-night effect may last more than one nightJournal of Psychiatric Research, 2001
- Evaluation of Home versus Laboratory Polysomnography in the Diagnosis of Sleep Apnea SyndromeAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Mild to Moderate Sleep Respiratory EventsChest, 2000
- Comparison of a limited computerized diagnostic system (ResCare Autoset) with polysomnography in the diagnosis of obstructive sleep apnoea syndromeEuropean Respiratory Journal, 1996