Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients
- 2 October 2012
- journal article
- clinical trial
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 21 (10) , 2281-2287
Abstract
Purpose: Tibiofemoral contact kinematics or knee implant motions have a direct influence on patient function and implant longevity and should be evaluated for any new alignment technique such as kinematically aligned total knee arthroplasty (TKA). Edge loading of the tibial liner and external rotation (reverse of normal) and adduction of the tibial component on the femoral component are undesirable contact kinematics that should be minimized. Accordingly, this study determined whether the overall prevalence of undesirable contact kinematics during standing, mid kneeling near 90 degrees and full kneeling with kinematically aligned TKA are minimal and not different between groups of consecutive patients treated by different surgeons.Methods: Three surgeons were asked to perform cemented, kinematically aligned TKA with patient‐specific guides in a consecutive series of patients with their preferred cruciate‐retaining (CR) implant. In vivo tibiofemoral contact positions were obtained using a 3‐ to 2‐dimensional image registration technique in 69 subjects (Vanguard CR–TKA N = 22, and Triathlon CR–TKA N = 47).Results: Anterior or posterior edge loading of the tibial liner was not observed. The overall prevalence of external rotation of the tibial component on the femoral component of 6 % was low and not different between surgeons (n.s.). The overall prevalence of adduction of the tibial component on the femoral component of 4 % was low and not different between surgeons (n.s.).Conclusions: Kinematically aligned TKA minimized the undesirable contact kinematics of edge loading of the tibial liner, and external rotation and adduction of the tibial component on the femoral component during standing and kneeling, which suggests an optimistic prognosis for durable long‐term function.Level of evidence: III.Keywords
This publication has 30 references indexed in Scilit:
- Kinematically Versus Mechanically Aligned Total Knee ArthroplastyOrthopedics, 2012
- An analysis of the Oxford hip and knee scores and their relationship to early joint revision in the New Zealand Joint RegistryThe Journal of Bone and Joint Surgery. British volume, 2010
- Method for Quantifying Patient Expectations and Early Recovery After Total Knee ArthroplastyOrthopedics, 2009
- Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignmentInternational Orthopaedics, 2008
- Kinematic analysis of kneeling in cruciate‐retaining and posterior‐stabilized total knee arthroplastiesJournal of Orthopaedic Research, 2007
- The role of pain and function in determining patient satisfaction after total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2007
- Determining the rotational alignment of the tibial component at total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2007
- Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2002
- Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopyIEEE Transactions on Biomedical Engineering, 1996
- Mechanisms of Failure of the Femoral and Tibial Components in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1989