Percutaneous instrumentation of the cervical and cervico-thoracic spine using pedicle screws: preliminary clinical results and analysis of accuracy
- 5 April 2011
- journal article
- ideas and-technical-innovations
- Published by Springer Nature in European Spine Journal
- Vol. 20 (6) , 977-985
Abstract
The pedicle screw instrumentation represents the most rigid construct of the cervical and cervicothoracic spine and in spite of the risks to neurovascular structures clinical relevant complications do not occur frequently. The steep angles of the cervical pedicles result in a wide surgical exposure with extensive muscular trauma. The objective of this study was the evaluation of the accuracy of cervical pedicle screw insertion through a minimally invasive technique to reduce access-related muscular trauma. Therefore, percutaneous transpedicular instrumentation of the cervical and cervicothoracic spine was performed in 15 patients using fluoroscopy. All instrumentations from C2 to Th4 were inserted bilaterally through 2 to 3-cm skin and fascia incisions even in multilevel procedures and the rods were placed by blunt insertion through the incision. Thin-cut CT scan was used postoperatively to analyze pedicle violations. 76.4% of 72 screws were placed accurately. Most pedicle perforations were seen laterally towards the vertebral artery. Critical breaches >2 mm or narrowing of the transversal foramen occurred in 12.5% of screws; however, no revision surgery for screw displacement was needed in the absence of clinical symptoms. No conversion from percutaneous to open surgery was necessary. It was concluded that percutaneous transpedicular instrumentation of the cervical spine is a surgically demanding technique and should be reserved for experienced spine surgeons. The indications are limited to instrumentation-only procedures or in combination with anterior treatment, but with the potential to minimize access-related morbidity.Keywords
This publication has 50 references indexed in Scilit:
- Clinical accuracy of cervical pedicle screw insertion using lateral fluoroscopy: a radiographic analysis of the learning curveEuropean Spine Journal, 2009
- Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscopeEuropean Spine Journal, 2009
- Indications for Cervical Pedicle Screw Instrumentation in Nontraumatic LesionsSpine, 2008
- Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literatureEuropean Spine Journal, 2008
- Percutaneous multilevel decompressive laminectomy, foraminotomy, and instrumented fusion for cervical spondylotic radiculopathy and myelopathy: assessment of feasibility and surgical techniqueJournal of Neurosurgery: Spine, 2007
- Minimally Invasive Lateral Mass Screw Fixation in the Cervical Spine: Initial Clinical Experience with Long-term Follow-upNeurosurgery, 2006
- Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric dataEuropean Spine Journal, 2006
- Complications of transpedicular screw fixation in the cervical spineEuropean Spine Journal, 2005
- The Accuracy of Computed Tomography in Assessing Cervical Pedicle Screw PlacementSpine, 2003
- Evaluation of Extracranial Vertebral Artery Dissection With Duplex Color-Flow ImagingStroke, 1996