Differences in perfusion CT parameter values with commercial software upgrades: a preliminary report about algorithm consistency and stability
- 1 September 2013
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 54 (7) , 805-811
Abstract
Computed tomographic perfusion (CTp) imaging is a promising technique that allows functional imaging, as an adjunct to a morphologic CT examination, that can be used as an aid to carefully evaluate the response to therapy in oncologic patients. Considering this statement, it could be desirable that the measurements obtained with the CT perfusion software, and their upgrades, are consistent and reproducible. To determine how commercial software upgrades impact on algorithm consistency and stability among the three version upgrades of the same platform in a preliminary study. Blood volume (BV), blood flow (BF), mean transit time (MTT), and permeability surface area product (PS) were calculated with repeated measurements (n = 1119) while truncating the time density curve at different time values in six CT perfusion studies using CT perfusion software version 4D (CT Perfusion 4D), then repeated with the previous version (CT Perfusion 3.0 and CT Perfusion 4.0), using a fixed ROI both for arterial input and target lesion. The software upgrades were compared in pairs by applying a Kolmogorov-Smirnov test to all the parameters measured. Stability and reliability of the three versions were verified through the variation of the truncated parameters. The three software versions provided different parent distributions for approximately 80% of the 72 parameters measured. A complete agreement was found only for one patient in version 3.0 vs. 4.0 and 3.0 vs. 4D. Perfusion 4.0 vs. 4D: a complete agreement was found only in two cases. Parameters obtained with Perfusion 4D always showed the lowest standard deviation in all temporal intervals and also for all individual parameters. The three versions of the same platform tested yield different perfusion measurements. Thus, our preliminary results show that Perfusion 4D version uses a stable deconvolution algorithm to provide more reliable measurements.Keywords
This publication has 8 references indexed in Scilit:
- Dynamic Contrast-Enhanced Computed Tomography Imaging Biomarkers Correlated With Immunohistochemistry for Monitoring the Effects of Sorafenib on Experimental Prostate CarcinomasInvestigative Radiology, 2012
- Monitoring Response to Antiangiogenic Treatment and Predicting Outcomes in Advanced Hepatocellular Carcinoma Using Image Biomarkers, CT Perfusion, Tumor Density, and Tumor Size (RECIST)Investigative Radiology, 2012
- Commercial software upgrades may significantly alter Perfusion CT parameter values in colorectal cancerEuropean Radiology, 2010
- Differences in CT Perfusion Maps Generated by Different Commercial Software: Quantitative Analysis by Using Identical Source Data of Acute Stroke PatientsRadiology, 2010
- Tumor Response in Patients With Advanced Non–Small Cell Lung Cancer: Perfusion CT Evaluation of Chemotherapy and Radiation TherapyAmerican Journal of Roentgenology, 2009
- Body Perfusion CT: Technique, Clinical Applications, and AdvancesRadiologic Clinics of North America, 2009
- Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to PracticeRadioGraphics, 2008
- Perfusion CT for the assessment of tumour vascularity: which protocol?British Journal of Radiology, 2003