Pupil Size Influence on the Intraocular Performance of the Multifocal AMO-Array Intraocular Lens in Elderly Patients
- 1 July 2007
- journal article
- research article
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 17 (4) , 571-578
Abstract
Purpose: To study the relationship between pupil size and AMO-Array multifocal intraocular lens (MIOL) performance in a population of elderly patients. Methods: This prospective trial included 62 patients (mean age 76 years; range 70 to 86) undergoing bilateral cataract phacoemulsification and MIOL (AMO-Array SA-40N, Allergan) implantation. Patients were divided into two groups based on preoperative pupil diameter: small pupil group (pupil size of 2.5–2.9 mm; 45 subjects) and large pupil group (pupil size of 3–5 mm; 17 subjects). The analysis included uncorrected (UC) and best-corrected (BC) near and distance visual acuity (VA), spectacle dependence, and photic phenomena complaints (postoperative follow-up 16.6±6.2 months; range 11–26 months). Results: Patients in the small pupil group showed postoperatively significantly higher distance UCVA and BCVA, but lower near UCVA compared to those in the large pupil group (Mann-Whitney test, p≤0.02). Patients with small pupils also tended to: be more (not statistically significant) spectacle independent for distance (73.3% versus 47.1%) and spectacle-dependent for near vision (55.6% versus 28.4%); report significantly less photic phenomena complaints (37.8% versus 93.1%, chi-square test, p<0.001); and, more satisfied with the surgery (95.5% versus 76.5%). Posterior capsular opacification (PCO) was observed in 19.4% of the patients. Conclusions: Bilateral AMO-Array MIOL implantation in elderly patients seems to be an effective and safe surgical procedure that improves distance and near UCVA, providing spectacle independence in many cases. The use of these MIOLs, however, can induce photic phenomena and cause PCO. Patients with small preoperative pupils (<3 mm) presented less photic phenomena complaints and expressed a higher visual outcome satisfaction after surgery.Keywords
This publication has 40 references indexed in Scilit:
- Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitroJournal of Cataract & Refractive Surgery, 2005
- Functional vision after cataract removal with multifocal and accommodating intraocular lens implantationJournal of Cataract & Refractive Surgery, 2004
- Refractive outcomes after bilateral multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2004
- Visual performance with multifocal intraocular lensesOphthalmology, 2004
- Multifocal versus monofocal intraocular lenses in cataract surgeryOphthalmology, 2003
- Correlation between pupillary size and intraocular lens decentration and visual acuity of a zonal-progressive multifocal lens and a monofocal lensOphthalmology, 2001
- Cataract extraction with multifocal intraocular lens implantation: Clinical, functional, and quality-of-life outcomesJournal of Cataract & Refractive Surgery, 2000
- A prospective comparative study of the amo array zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lensOphthalmology, 1999
- The Julius F. Neumueller Award in Optics, 1989: Change of Pupil Centration with Change of Illumination and Pupil SizeOptometry and Vision Science, 1992
- Effect of cataract extraction on the pupil response to mydriatics.British Journal of Ophthalmology, 1989