Purpose: To investigate four‐dimensional flow denoising using the divergence‐free wavelet (DFW) transform and compare its performance with existing techniques.Theory and Methods: DFW is a vector‐wavelet that provides a sparse representation of flow in a generally divergence‐free field and can be used to enforce “soft” divergence‐free conditions when discretization and partial voluming result in numerical nondivergence‐free components. Efficient denoising is achieved by appropriate shrinkage of divergence‐free wavelet and nondivergence‐free coefficients. SureShrink and cycle spinning are investigated to further improve denoising performance.Results: DFW denoising was compared with existing methods on simulated and phantom data and was shown to yield better noise reduction overall while being robust to segmentation errors. The processing was applied to in vivo data and was demonstrated to improve visualization while preserving quantifications of flow data.Conclusion: DFW denoising of four‐dimensional flow data was shown to reduce noise levels in flow data both quantitatively and visually. Magn Reson Med 73:828–842, 2015. © 2014 Wiley Periodicals, Inc.Keywords
Funding Information
- NIH (P41RR09784, R01EB009690)
- American Heart Association (12BGIA9660006)
- The Sloan Research Fellowship
This publication has 34 references indexed in Scilit:
- Coil compression for accelerated imaging with Cartesian samplingMagnetic Resonance in Medicine, 2012
- SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐spaceMagnetic Resonance in Medicine, 2010
- Improved SNR in phase contrast velocimetry with five‐point balanced flow encodingMagnetic Resonance in Medicine, 2010
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Divergence-free and curl-free wavelets in two dimensions and three dimensions: application to turbulent flowsJournal of Turbulence, 2006
- Time‐resolved three‐dimensional phase‐contrast MRIJournal of Magnetic Resonance Imaging, 2003
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Adapting to Unknown Smoothness via Wavelet ShrinkageJournal of the American Statistical Association, 1995
- Noise reduction in three‐dimensional phase‐contrast MR velocity measurementslJournal of Magnetic Resonance Imaging, 1993
- Semiautomated method for noise reduction and background phase error correction in MR phase velocity dataJournal of Magnetic Resonance Imaging, 1993