Are fixed-rate step tests medically safe for assessing physical fitness?
- 4 March 2011
- journal article
- clinical trial
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 111 (10) , 2593-2599
Abstract
Maximal oxygen uptake (VO2max) can be predicted by fixed-rate step tests. However, it remains to be analyzed as to what exercise intensities are reached during such tests to address medical safety. In this study, we compared the physiological response to a standardized fixed-rate step test with maximal cardiopulmonary exercise testing (CPET). One hundred and thirteen healthy adults executed a maximal CPET on bike, followed by a standardized fixed-rate step test 1 week later. During these tests, heart rate (HR) and VO2 were monitored continuously. From the maximal CPET, the ventilatory threshold (VT) was calculated. Next, the physiological response between maximal CPET and step testing was compared. The step test intensity was 85 ± 24% CPET VO2max and 88 ± 11% CPET HRmax (VO2max and HRmax were significantly different between CPET and step testing; p < 0.01). In 41% of the subjects, step test exercise intensities >95% CPET VO2max were noted. A greater step testing exercise intensity (%CPET VO2max) was independently related to higher body mass index, and lower body height, exercise capacity (p < 0.05). Standardized fixed-rate step tests elicit vigorous exercise intensities, especially in small, obese, and/or physically deconditioned subjects. Medical supervision might therefore be required during these tests.Keywords
This publication has 25 references indexed in Scilit:
- Exercise intensity: Platelet function and platelet–leukocyte conjugate formation in untrained subjectsThrombosis Research, 2008
- Exercise and Acute Cardiovascular EventsCirculation, 2007
- Reliability and validity of measures taken during the Chester step test to predict aerobic power and to prescribe aerobic exerciseBritish Journal of Sports Medicine, 2004
- International Physical Activity Questionnaire: 12-Country Reliability and ValidityMedicine & Science in Sports & Exercise, 2003
- High Intensity Exercise Enhances Platelet Reactivity to Shear Stress and Coagulation during and after ExercisePathophysiology of Haemostasis and Thrombosis, 2003
- Exercise Standards for Testing and TrainingCirculation, 2001
- Triggering of Sudden Death from Cardiac Causes by Vigorous ExertionNew England Journal of Medicine, 2000
- Aerobic Requirement of Bench SteppingInternational Journal of Sports Medicine, 1993
- Endurance fitness and blood lactate concentration during stepping exercise in untrained subjects.British Journal of Sports Medicine, 1989
- A simple and portable paced step test for reproducible measurements of ventilation and oxygen consumption during exercise.Thorax, 1987