Sensitivity of Piezoelectric-Based Smart Interfaces to Structural Damage in Bolted Connections
Open Access
Abstract
This study presents a set of experimental and numerical investigations to study the sensitivity of the piezoelectric-based smart interface device to structural damage in a bolted connection. The study aims to identify the proper geometric sizes of smart interfaces for damage detection tasks. First, the fundamentals of the damage monitoring technique via lead zirconate titanate (PZT) interface is briefly described for a bolted connection. Second, a lab-scaled girder connection is selected as the test structure for the experimental investigation. PZT interface prototypes with varying geometric sizes are designed for the test connection. Under the bolt-loosening inflicted in the connection, the impedance responses of the PZT interfaces are analyzed to understand the effect of geometric parameters on the damage sensitivity of the impedance responses. Subsequently, the bolt-loosening detection capabilities of the PZT interfaces are comparatively evaluated for identifying the proper geometric sizes of the devices. Finally, a finite element model of the PZT interface-bolted connection system is established for the numerical investigation. The damage sensitivity of the numerical impedance responses is compared with the experimental results for the verification.Keywords
Funding Information
- National Research Foundation of Korea (NRF2016R1A2B4015087)
This publication has 36 references indexed in Scilit:
- Quasi-autonomous bolt-loosening detection method using vision-based deep learning and image processingAutomation in Construction, 2019
- A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering StructuresSensors, 2018
- Hybrid bolt-loosening detection in wind turbine tower structures by vibration and impedance responsesWind and Structures, 2017
- Application of subharmonic resonance for the detection of bolted joint loosenessNonlinear Dynamics, 2017
- Vision-based technique for bolt-loosening detection in wind turbine towerWind and Structures, 2015
- Bolt loosening analysis and diagnosis by non-contact laser excitation vibration testsMechanical Systems and Signal Processing, 2013
- Impedance-based structural health monitoring incorporating neural network technique for identification of damage type and severityEngineering Structures, 2012
- Application of Electromechanical Impedance Technique for Engineering Structures: Review and Future IssuesJournal of Intelligent Material Systems and Structures, 2009
- Overview of Piezoelectric Impedance-Based Health Monitoring and Path ForwardThe Shock and Vibration Digest, 2003
- Feasibility of using impedance‐based damage assessment for pipeline structuresEarthquake Engineering & Structural Dynamics, 2001