Entropy Generation in Counter Flow Gas to Gas Heat Exchangers
- 13 April 2005
- journal article
- Published by Wiley in Journal of Heat Transfer
- Vol. 128 (1) , 87-92
Abstract
Analysis of heat transfer and fluid flow thermodynamic irreversibilities is realized on an example of a counter flow double pipe heat exchanger utilizing turbulent air flow as a working fluid. During the process of mathematical model creation and for different working and constructing limitations, total thermodynamic irreversibility is studied. The present work proves that the irreversibility occurred due to unequal capacity flow rates (flow imbalance irreversibility). It is concluded that the heat exchanger should be operated at effectiveness, ε, greater than 0.5 and the well operating conditions will be achieved when ε approaches one where low irreversibility is expected. A new equation is adopted to express the entropy generation numbers for imbalanced heat exchangers of similar design with smallest deviation from the exact value. The results obtained from the new equation are compared with the exact values and with those obtained by Bejan (Bejan, A., 1997, Advanced Engineering Thermodynamics, Wiley, New York).Keywords
This publication has 6 references indexed in Scilit:
- Entropy generation minimization: The new thermodynamics of finite-size devices and finite-time processesJournal of Applied Physics, 1996
- Theory of the exergetic costEnergy, 1993
- An Extension to the Irreversibility Minimization Analysis Applied to Heat ExchangersJournal of Heat Transfer, 1989
- Equipartition of entropy production. An optimality criterion for transfer and separation processesIndustrial & Engineering Chemistry Research, 1987
- Entropy Generation Through Heat and Fluid FlowJournal of Applied Mechanics, 1983
- The Concept of Irreversibility in Heat Exchanger Design: Counterflow Heat Exchangers for Gas-to-Gas ApplicationsJournal of Heat Transfer, 1977