Pharmacokinetics of Depemokimab Delivered by Safety Syringe Device or Autoinjector in Healthy Adults: A Phase 1, Single‐Dose Study
Open Access
- 28 January 2025
- journal article
- research article
- Published by Wiley in Clinical Pharmacology in Drug Development
- Vol. 14 (3) , 190-199
Abstract
This Phase I, randomized, multicenter, open‐label, parallel‐group, single‐dose study assessed the relative bioavailability of the anti–interleukin‐5 antibody depemokimab (100 mg) when administered subcutaneously via either a safety syringe device (SSD) or an autoinjector (AI). Healthy adult participants were randomized I:I to SSD or AI treatment arms and I:I:I to the injection site (upper arm, abdomen, or thigh). Participants were followed up for 30 weeks; blood samples were collected for pharmacokinetic (PK) assessment before dosing on Day 1 and up to Week 26. Depemokimab concentration profile as measured by plasma maximum concentration (Cmax), the area under the concentration–time curve from time zero extrapolated to infinity (AUC0‐inf), PK parameters, immunogenicity, and safety were assessed. Overall, 140 participants were enrolled (n = 70 per arm). Mean plasma concentration‐time profiles of depemokimab were similar in both treatment arms, regardless of the injection site, adjusted geometric mean AI:SSD ratios for Cmax and AUC0‐inf were 1.03 and 1.03, respectively, with all 90% confidence intervals within the bioequivalence bounds of 0.80‐1.25. PK parameters were comparable across treatment arms. Treatment‐related adverse events were reported in 19% of SSD and 20% of AI participants, with headache being the most common across both arms; no adverse events led to study withdrawal. These results support the use of either SSD or AI for subcutaneous administration of depemokimab.Keywords
This publication has 19 references indexed in Scilit:
- Twice-Yearly Depemokimab in Severe Asthma with an Eosinophilic PhenotypeThe New England journal of medicine, 2024
- The Adherence and Outcomes Benefits of Using a Connected, Reusable Auto-Injector for Self-Injecting Biologics: A Narrative ReviewAdvances in Therapy, 2023
- Real-world severe asthma biologic administration and adherence differs by biologicAnnals of Allergy, Asthma & Immunology, 2023
- Perceptions on Home-Administration of Biologics in the Context of Severe Asthma: An International Qualitative StudyThe Journal of Allergy and Clinical Immunology: In Practice, 2022
- Biologic Therapies for Severe AsthmaThe New England journal of medicine, 2022
- Understanding and Minimising Injection-Site Pain Following Subcutaneous Administration of Biologics: A Narrative ReviewRheumatology and Therapy, 2020
- Comparison of autoinjector with accessorized prefilled syringe for benralizumab pharmacokinetic exposure: AMES trial resultsJournal of Asthma, 2019
- The Pharmacokinetics and Relative Bioavailability of Mepolizumab 100 mg Liquid Formulation Administered Subcutaneously to Healthy Participants: A Randomized TrialClinical Pharmacology in Drug Development, 2019
- Usability of mepolizumab single-use prefilled autoinjector for patient self-administrationJournal of Asthma, 2019
- Usability of mepolizumab single-use prefilled syringe for patient self-administrationJournal of Asthma, 2019