Similar kinematic patterns between revision total stabilized (TS) and primary posterior stabilized (PS) knee prostheses: a prospective case–controlled study with gait assessment
- 4 May 2021
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (8) , 2714-2722
Abstract
Purpose: There are increased surgical considerations when revising total knee arthroplasty (TKA) in active patients. Few studies have assessed if a semi‐constrained [Total Stabilized (TS)] prostheses has similar knee biomechanics to a primary posterior stabilized (PS) prosthesis. The aim was to compare the gait parameters in patients with PS or TS TKA and normal controls.Methods: 32 patients with TKA were prospectively included with either a primary PS (n = 15) or a revision TS (n = 17) prosthesis. Gait analysis was performed at 6 months postoperatively for each patient, with an optoelectronic knee assessment device (KneeKG®) assessing the displacement of the tibia relative to the femur during the different gait phases (flexion/extension, anterior/posterior translation, adduction/abduction, internal/external rotation). A control group (n = 12) of healthy knees was compared with the TKA groups.Results: There were no significant kinematic differences between PS and TS groups. The maximum knee flexion during gait was 53° ± 8.1° in the PS group vs 52° ± 8.7° in the TS group. The antero‐posterior translation was similar in both group (2.3 ± 0.5 mm vs 2.6 ± 0.9 mm, respectively). Peak varus angle during loading and swing phase was slightly higher in the TS group (2.7° ± 0.7° and 5.2° ± 0.9°) than in the PS group (2.9° ± 0.6° and 5.6° ± 1.2°), without significant difference. The ranges in internal/external rotation were similar between PS and TS TKA (3.7° ± 0.5° vs 3.3° ± 0.6°, respectively). Both designs approached closely the normal gait patterns of the control group except in the frontal plane.Conclusion: Single radius TS TKA has gait parameters similar to single radius PS TKA. Use of a single radius TS TKA in revision TKA is not detrimental to a patient’s gait pattern. Both designs approached closely the normal gait patterns of the control group.Level of evidence: Prospective, case–control study; Level III.Keywords
Funding Information
- Stryker (40,115 €)
- Stryker (40,115 €)
This publication has 32 references indexed in Scilit:
- In Vivo Movement of Femoral Flexion Axis of a Single-Radius Total Knee ArthroplastyThe Journal of Arthroplasty, 2014
- Gait knee kinematic alterations in medial osteoarthritis: three dimensional assessmentInternational Orthopaedics, 2014
- The Effects of Hamstring Stretching on Leg Rotation during Knee ExtensionJournal of Physical Therapy Science, 2013
- Constraints in posterior‐stabilised TKA kinematics: a comparison of two generations of an implantKnee Surgery, Sports Traumatology, Arthroscopy, 2012
- Reason for Revision Influences Early Patient Outcomes After Aseptic Knee RevisionClinical Orthopaedics and Related Research, 2012
- When Do Patient-reported Assessments Peak after Revision Knee Arthroplasty?Clinical Orthopaedics and Related Research, 2012
- The KneeKG system: a review of the literatureKnee Surgery, Sports Traumatology, Arthroscopy, 2012
- Functional outcome after total knee arthroplasty revisionThe Journal of Arthroplasty, 2002
- Quantitative gait analysis after bilateral total knee arthroplasty with two different systems within each subjectThe Journal of Arthroplasty, 1997
- The “Screw-Home” Movement in the Knee-JointActa Orthopaedica, 1966