3.0 Tesla imaging of the musculoskeletal system
Authors:
- 26 January 2007
- journal article
- review article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 25 (2) , 245-261
Abstract
High‐field MRI at 3.0T is rapidly gaining clinical acceptance and experiencing more widespread use. The superiority of high‐field imaging has clearly been demonstrated for neurological imaging. The impact of 3.0T imaging of the musculoskeletal system has been less dramatic due to complex optimization issues. Areas under consideration include coil technology, protocol modification, artifact reduction, and patient safety. In this article we review these issues and describe our experience with 3.0T musculoskeletal MRI. Fundamentally, an increased signal‐to‐noise ratio (SNR) is responsible for improved imaging at higher field strength. Increased SNR allows more headroom to adjust parameters that affect image resolution and examination time. It has been established that T1 relaxation time increases at 3.0T, while T2 time decreases. Consequently, scanner parameters require adjustment for optimization of images. Chemical shift and magnetic susceptibility artifacts are more pronounced and require special techniques to minimize the effect on image quality. Spectral fat saturation techniques can take advantage of the increased chemical shift. The specific absorption rate (SAR) and acoustic noise thresholds must be kept in mind at these higher fields. We additionally present some of the clinical issues we have experienced at 3.0T. A decision must be made as to whether to trade higher resolution for reduced scanning time. In general, we believe that routine imaging at 3.0T increases diagnostic confidence, especially for evaluations of cartilaginous and ligamentous structures. J. Magn. Reson. Imaging 2007.Keywords
This publication has 64 references indexed in Scilit:
- Musculoskeletal tumors: Use of proton MR spectroscopic imaging for characterizationJournal of Magnetic Resonance Imaging, 2005
- Assessment of magnetic field (4.7 T) induced forces on prosthetic heart valves and annuloplasty ringsJournal of Magnetic Resonance Imaging, 2005
- Quantitative evaluation of metal artifact reduction techniquesJournal of Magnetic Resonance Imaging, 2004
- High field human imagingJournal of Magnetic Resonance Imaging, 2003
- Randomized comparison of cognitive function in humans at 0 and 8 TeslaJournal of Magnetic Resonance Imaging, 2003
- An MR Transceive Phased Array Designed for Spinal Cord Imaging at 3 Tesla: Preliminary Investigations of Spinal Cord Imaging at 3 TInvestigative Radiology, 2003
- Projectile Cylinder Accidents Resulting from the Presence of Ferromagnetic Nitrous Oxide or Oxygen Tanks in the MR SuiteAmerican Journal of Roentgenology, 2001
- The Loss of Small Objects in Variable TE Imaging: Implications for FSE, RARE, and EPIMagnetic Resonance in Medicine, 1992
- Edge Artifacts in MR ImagesJournal of Computer Assisted Tomography, 1985
- RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imagingPhysics in Medicine & Biology, 1978