Optimization of Spiral-Wound Microfiltration Process Parameters for the Production of Micellar Casein Concentrate
Open Access
Abstract
A systematic selection of different transmembrane pressures (TMP) and levels of diafiltration (DF) was studied to optimize these critical process parameters during the manufacturing of micellar casein concentrate (MCC) using spiral-wound polymeric membrane filtration. Three TMPs (34.5, 62.1, and 103.4 kPa) and four DF levels (0, 70, 100, and 150%) were applied in the study. The effect of the TMP and DF level on flux rates, serum protein (SP) removal, the casein-to-total-protein ratio, the casein-to-true-protein ratio, and the rejection of casein and SP were evaluated. At all transmembrane pressures, the overall flux increased with increases in the DF level. The impact of DF on the overall flux was more pronounced at lower pressures than at higher pressures. With controlled DF, the instantaneous flux was maintained within 80% of the initial flux for the entire process run. The combination of 34.5 kPa and a DF level of 150% resulted in 81.45% SP removal, and a casein-to-true-protein ratio of 0.96. SP removal data from the lab-scale experiments were fitted into a mathematical model using DF levels and the square of TMPs as factors. The model developed in this study could predict SP removal within 90–95% of actual SP removal achieved from the pilot plant experiments.Keywords
All Related Versions
This publication has 21 references indexed in Scilit:
- Effect of ceramic membrane channel diameter on limiting retentate protein concentration during skim milk microfiltrationJournal of Dairy Science, 2016
- The effect of linear velocity and flux on performance of ceramic graded permeability membranes when processing skim milk at 50°CJournal of Dairy Science, 2014
- Use of micellar casein concentrate for Greek-style yogurt manufacturing: Effects on processing and product propertiesJournal of Dairy Science, 2014
- Production of an 18% protein liquid micellar casein concentrate with a long refrigerated shelf lifeJournal of Dairy Science, 2013
- Micellar casein concentrate production with a 3X, 3-stage, uniform transmembrane pressure ceramic membrane process at 50°CJournal of Dairy Science, 2010
- Production efficiency of micellar casein concentrate using polymeric spiral-wound microfiltration membranesJournal of Dairy Science, 2010
- Processing factors that influence casein and serum protein separation by microfiltrationJournal of Dairy Science, 2010
- Efficiency of serum protein removal from skim milk with ceramic and polymeric membranes at 50°CJournal of Dairy Science, 2009
- Microfiltration of skim milk using polymeric membranes for casein concentrate manufactureSeparation and Purification Technology, 2008
- Use of Cold Microfiltration Retentates Produced with Polymeric Membranes for Standardization of Milks for Manufacture of Pizza CheeseJournal of Dairy Science, 2007