Modulation transfer function assessment in parallel beam and fan beam collimators with square and cylindrical holes
- 26 February 2014
- journal article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 28 (4) , 363-370
Abstract
This study investigates modulation transfer function (MTF) in parallel beam (PB) and fan beam (FB) collimators using the Monte Carlo method with full width at half maximum (FWHM), square and circular-shaped holes, and scatter and penetration (S + P) components. A regulation similar to the lead-to-air ratio was used for both collimators to estimate output data. The hole pattern was designed to compare FB by PB parameters. The radioactive source in air and in a water phantom placed in front of the collimators was simulated using MCNP5 code. The test results indicated that the square holes in PB (PBs) had better FWHM than did the cylindrical (PBc) holes. In contrast, the cylindrical holes in the FB (FBc) had better FWHM than the square holes. In general, the resolution of FBc was better than that of the PBc in air and scatter mediums. The S + P decreased for all collimators as the distance from the source to the collimator surface (z) increased. The FBc had a lower S + P than FBs, but PBc had a higher S + P than PBs. Of the FB and PB collimators with the identical hole shapes, PBs had a smaller S + P than FBs, and FBc had a smaller S + P than PBc. The MTF value for the FB was greater than for the PB and had increased spatial frequency; the FBc had higher MTF than the FBs and PB collimators. Estimating the FB using PB parameters and diverse hole shapes may be useful in collimator design to improve the resolution and efficiency of SPECT images.Keywords
This publication has 11 references indexed in Scilit:
- Imaging in Nuclear Medicine2013
- Evaluation of collimators' response: Round and hexagonal holes in parallel and fan beamProgress in Biophysics and Molecular Biology, 2012
- Performance characteristics of the SMARTZOOM® collimator2011
- SIMIND Monte Carlo simulation of a single photon emission CTJournal of Medical Physics, 2010
- Modeling of the sensitivity of fan-beam collimation in SPECT imaging2005
- Monte Carlo simulation in PET and SPECT instrumentation using GATENuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- A parallel Monte Carlo code for planar and SPECT imaging: implementation, verification and applications in 131I SPECTComputer Methods and Programs in Biomedicine, 2002
- Importance of the choice of the collimator for the detection of small lesions in scintimammography: a phantom studyPhysics in Medicine & Biology, 2001
- The geometric transfer function component for scintillation camera collimators with straight parallel holesPhysics in Medicine & Biology, 1980
- Single Photon Emission Computed Tomography Using Multi-Slice Fan Beam CollimatorsIEEE Transactions on Nuclear Science, 1979