Reliability of a New Digital Tool for Photographic Analysis in Quantifying Body Asymmetry in Scoliosis
Authors:
- Javier PizonesJPJavier Pizones
- Lucía Moreno-ManzanaroLMLucía Moreno-Manzanaro
- Anika PupakAPAnika Pupak
- Susana Núñez-PereiraSNSusana Núñez-Pereira
- Daniel LarrieuDLDaniel Larrieu
- Louis BoissiereLBLouis Boissiere
- Sarah Richner-WunderlinSRSarah Richner-Wunderlin
- Markus LoiblMLMarkus Loibl
- Tais ZulemyanTZTais Zulemyan
- Altug YücekulAYAltug Yücekul
- Sara ZgheibSZSara Zgheib
- Yann Philippe CharlesYCYann Philippe Charles
Open Access
- 5 April 2024
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (7) , 2114
Abstract
Background: Advancements in non-ionizing methods for quantifying spinal deformities are crucial for assessing and monitoring scoliosis. In this study, we analyzed the observer variability of a newly developed digital tool for quantifying body asymmetry from clinical photographs. Methods: Prospective observational multicenter study. Initially, a digital tool was developed using image analysis software, calculating quantitative measures of body asymmetry. This tool was integrated into an online platform that exports data to a database. The tool calculated 10 parameters, including angles (shoulder height, axilla height, waist height, right and left waistline angles, and their difference) and surfaces of the left and right hemitrunks (shoulders, waists, pelvises, and total). Subsequently, an online training course on the tool was conducted for twelve observers not involved in its development (six research coordinators and six spine surgeons). Finally, 15 standardized back photographs of adolescent idiopathic scoliosis patients were selected from a multicenter image bank, representing various clinical scenarios (different age, gender, curve type, BMI, and pre- and postoperative images). The 12 observers measured the photographs at two different times with a three-week interval. For the second round, the images were randomly mixed. Inter- and intra-observer variabilities of the measurements were analyzed using intraclass correlation coefficients (ICCs), and reliability was measured by the standard error of measurement (SEM). Group comparisons were made using Student’s t-test. Results: The mean inter-observer ICC for the ten measurements was 0.981, the mean intra-observer ICC was 0.937, and SEM was 0.3–1.3°. The parameter with the strongest inter- and intra-observer validity was the difference in waistline angles 0.994 and 0.974, respectively, while the highest variability was found with the waist height angle 0.963 and 0.845, respectively. No test–retest differences (p > 0.05) were observed between researchers (0.948 ± 0.04) and surgeons (0.925 ± 0.05). Conclusion: We developed a new digital tool integrated into an online platform demonstrating excellent reliability and inter- and intra-observer variabilities for quantifying body asymmetry in scoliosis patients from a simple clinical photograph. The method could be used for assessing and monitoring scoliosis and body asymmetry without radiation.Keywords
Funding Information
- DePuy Synthes Spine
- Medtronic
This publication has 45 references indexed in Scilit:
- Reliability of automated topographic measurements for spine deformitySpine Deformity, 2022
- Establishing the validity of surface topography for assessment of scoliosis: a prospective studySpine Deformity, 2021
- Geometric morphometrics of adolescent idiopathic scoliosis: a prospective observational studyEuropean Spine Journal, 2020
- Reliability and validity of lateral curvature assessments using clinical ultrasound for the patients with scoliosis: a systematic reviewEuropean Spine Journal, 2020
- Clinical photography in severe idiopathic scoliosis candidate for surgery: is it a useful tool to differentiate among Lenke patterns?European Spine Journal, 2019
- Validity and reliability of photographic measures to evaluate waistline asymmetry in idiopathic scoliosisEuropean Spine Journal, 2016
- Outcome instruments to assess scoliosis surgeryEuropean Spine Journal, 2012
- Discrepancy between radiographic shoulder balance and cosmetic shoulder balance in adolescent idiopathic scoliosis patients with double thoracic curveEuropean Spine Journal, 2008
- Reliability of trunk shape measurements based on 3-D surface reconstructionsEuropean Spine Journal, 2007
- Quantification of cosmesis for patients affected by adolescent idiopathic scoliosisEuropean Spine Journal, 1998