Analysis of Cardiac Function???Comparison Between 1.5 Tesla and 3.0 Tesla Cardiac Cine Magnetic Resonance Imaging
Authors:
- Henrik J. MichaelyHMHenrik J. Michaely
- Kambiz NaelKNKambiz Nael
- Stefan O. SchoenbergSSStefan O. Schoenberg
- Gerhard LaubGLGerhard Laub
- Maximilian F. ReiserMRMaximilian F. Reiser
- J Paul FinnJFJ Paul Finn
- Stefan G. RuehmSRStefan G. Ruehm
- 1 February 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 41 (2) , 133-140
Abstract
We sought to assess the feasibility of magnetic resonance imaging to evaluate cardiac function at 3.0 T compared with 1.5 T. In a prospective intraindividual comparative study, 12 volunteers (range, 18–54 years), and 2 patients (range, 43–53 years) underwent cardiac cine magnetic resonance at both 3.0 T and 1.5 T. Data were acquired both with a steady-state free precession sequence (SSFP) and a spoiled gradient echo (SGE) sequence. If necessary, a frequency scout was used to correct for off-resonance artifacts. For both SSFP and SGE imaging, 6-mm thick retrospectively EKG-gated short axis views were acquired with equal matrix size (192 × 163) and comparable repetition time (TR). Cardiac function parameters were determined manually by a single investigator. Cardiac function parameters, signal to noise ratio (SNR), contrast to noise ratio (CNR), and the presence of artifacts were compared between the 2 magnetic field strengths. For statistical analysis, a Pearson's correlation coefficient was calculated, and a paired Student t test was used to test statistical significance. Very good correlations between cardiac function parameters at 1.5 T and 3.0 T (r > 0.84, P < 0.0011) were obtained. Compared with SGE, SSFP more frequently was prone to artifacts. With SSFP/SGE at 3.0 T, a SNR gain of 9.4/16% was achieved compared with 1.5 T. Functional cardiac cine magnetic resonance imaging can be regarded as equally accurate at 3.0 T compared with 1.5 T. Compared with SSFP imaging, the SGE sequence benefits more from higher field strengths and is less affected by artifacts.Keywords
This publication has 20 references indexed in Scilit:
- Breath-hold FLASH and FISP Cardiovascular MR Imaging: Left Ventricular Volume Differences and ReproducibilityRadiology, 2002
- Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State PrecessionRadiology, 2001
- MR Evaluation of Ventricular Function: True Fast Imaging with Steady-State Precession versus Fast Low-Angle Shot Cine MR Imaging: Feasibility StudyRadiology, 2001
- Volumetric analysis of the right and left ventricle in a porcine heart model: comparison of three-dimensional echocardiography, magnetic resonance imaging and angiocardiographyEuropean Journal of Ultrasound, 1999
- Alternative projections of mortality and disability by cause 1990–2020: Global Burden of Disease StudyThe Lancet, 1997
- Which standard has the gold?JACC, 1992
- Cardiac ejection fraction: Phantom study comparing cine MR imaging, radionuclide blood pool imaging, and ventriculographyJournal of Magnetic Resonance Imaging, 1992
- Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.Radiology, 1991
- Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction.Circulation, 1987
- Determinants of Prognosis in Survivors of Myocardial InfarctionNew England Journal of Medicine, 1982