Review on design and control aspects of ankle rehabilitation robots
- 9 December 2013
- journal article
- review article
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 10 (2) , 93-101
Abstract
Ankle rehabilitation robots can play an important role in improving outcomes of the rehabilitation treatment by assisting therapists and patients in number of ways. Consequently, few robot designs have been proposed by researchers which fall under either of the two categories, namely, wearable robots or platform-based robots. This paper presents a review of both kinds of ankle robots along with a brief analysis of their design, actuation and control approaches. While reviewing these designs it was observed that most of them are undesirably inspired by industrial robot designs. Taking note of the design concerns of current ankle robots, few improvements in the ankle robot designs have also been suggested. Conventional position control or force control approaches, being used in the existing ankle robots, have been reviewed. Apparently, opportunities of improvement also exist in the actuation as well as control of ankle robots. Subsequently, a discussion on most recent research in the development of novel actuators and advanced controllers based on appropriate physical and cognitive human–robot interaction has also been included in this review.Keywords
This publication has 51 references indexed in Scilit:
- A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibitionJournal of NeuroEngineering and Rehabilitation, 2009
- Review of control strategies for robotic movement training after neurologic injuryJournal of NeuroEngineering and Rehabilitation, 2009
- A High-performance Redundantly Actuated Parallel Mechanism for Ankle RehabilitationThe International Journal of Robotics Research, 2009
- Design and Implementation of an Assistive Controller for Rehabilitation Robotic SystemsInternational Journal of Advanced Robotic Systems, 2007
- Robotics, Motor Learning, and Neurologic RecoveryAnnual Review of Biomedical Engineering, 2004
- Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gaitIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2004
- Upper and lower extremity robotic devices for rehabilitation and for studying motor controlCurrent Opinion in Neurology, 2003
- Disturbance observer and feedforward design for a high-speed direct-drive positioning tableIEEE Transactions on Control Systems Technology, 1999
- Stability and Performance Limits of Interaction ControllersJournal of Dynamic Systems, Measurement, and Control, 1992
- Robust control of dynamically interacting systemsInternational Journal of Control, 1988