Evaluation of dicationic reagents for their use in detection of anions using positive ion mode ESI-MS via gas phase ion association
Authors:
- 1 February 2008
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 19 (2) , 261-269
Abstract
Twenty-three different dications were investigated for their effectiveness in pairing with singly charged anions, thereby allowing the electrospray ionization mass spectrometry (ESI-MS) detection of anions as positively charged complexes. Nitrate, iodide, cyanate, monochloroacetate, benzenesulfonate, and perfluoro-octanoate were chosen as representative test anions as they differ in mass, size-to-charge ratio, chaotropic nature, and overall complexity. Detection limits were found using direct injection of the anion into a carrier liquid containing the dication. Detection limits are given for all six anions with each of the 23 dications. Each anion was easily detected at the ppb (microg/L) and often the ppt (ng/L) levels using certain dicationic reagents. The ability of dicationic reagents to pair with anions and produce ESI-MS signals varied tremendously. Indeed, only a few dications can be considered broadly useful and able to produce sensitive results. Liquid chromatography (LC)-ESI-MS also was investigated and used to show how varying the dicationic reagent produced significantly different peak intensities. Also, the use of tandem mass spectrometry can lead to even greater sensitivity when using imidazolium based dications.Keywords
This publication has 23 references indexed in Scilit:
- Unsymmetrical Dicationic Ionic Liquids: Manipulation of Physicochemical Properties Using Specific Structural ArchitecturesChemistry of Materials, 2007
- Ion Mobility Spectrometry: Principles and ApplicationsApplied Spectroscopy Reviews, 2006
- Matrix interference free determination of perchlorate in urine by ion association–ion chromatography–mass spectrometryAnalytica Chimica Acta, 2006
- Perchlorate in seawaterAnalytica Chimica Acta, 2006
- Sample processing method for the determination of perchlorate in milkAnalytica Chimica Acta, 2006
- Structure and Properties of High Stability Geminal Dicationic Ionic LiquidsJournal of the American Chemical Society, 2004
- Capillary ion chromatographyJournal of Separation Science, 2004
- Peer Reviewed: Tracing the History of Selective Ion SensorsAnalytical Chemistry, 2001
- Charge‐state distributuion and electric‐discharge suppression in negative‐ion electrospray mass spectrometry using/chlorinated solventsRapid Communications in Mass Spectrometry, 1992
- Electrospray interface for liquid chromatographs and mass spectrometersAnalytical Chemistry, 1985