Orientationally invariant metrics of apparent compartment eccentricity from double pulsed field gradient diffusion experiments
- 23 August 2013
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 26 (12) , 1647-1662
Abstract
Pulsed field gradient diffusion sequences (PFG) with multiple diffusion encoding blocks have been indicated to offer new microstructural tissue information, such as the ability to detect nonspherical compartment shapes in macroscopically isotropic samples, i.e. samples with negligible directional signal dependence on diffusion gradients in standard diffusion experiments. However, current acquisition schemes are not rotationally invariant in the sense that the derived metrics depend on the orientation of the sample, and are affected by the interplay of sampling directions and compartment orientation dispersion when applied to macroscopically anisotropic systems. Here we propose a new framework, the d‐PFG 5‐design, to enable rotationally invariant estimation of double wave vector diffusion metrics (d‐PFG). The method is based on the idea that an appropriate orientational average of the signal emulates the signal from a powder preparation of the same sample, where macroscopic anisotropy is absent by construction. Our approach exploits the theory of exact numerical integration (quadrature) of polynomials on the rotation group, and we exemplify the general procedure with a set consisting of 60 pairs of diffusion wave vectors (the d‐PFG 5‐design) facilitating a theoretically exact determination of the fourth order Taylor or cumulant expansion of the orientationally averaged signal. The d‐PFG 5‐design is evaluated with numerical simulations and ex vivo high field diffusion MRI experiments in a nonhuman primate brain. Specifically, we demonstrate rotational invariance when estimating compartment eccentricity, which we show offers new microstructural information, complementary to that of fractional anisotropy (FA) from diffusion tensor imaging (DTI). The imaging observations are supported by a new theoretical result, directly relating compartment eccentricity to FA of individual pores. Copyright © 2013 John Wiley & Sons, Ltd.Keywords
This publication has 50 references indexed in Scilit:
- Towards compartment size estimation in vivo based on double wave vector diffusion weightingNMR in Biomedicine, 2011
- The displacement correlation tensor: Microstructure, ensemble anisotropy and curving fibersJournal of Magnetic Resonance, 2011
- Pore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantomJournal of Magnetic Resonance, 2011
- From single‐pulsed field gradient to double‐pulsed field gradient MR: gleaning new microstructural information and developing new forms of contrast in MRINMR in Biomedicine, 2010
- Measuring small compartmental dimensions with low-q angular double-PGSE NMR: The effect of experimental parameters on signal decayJournal of Magnetic Resonance, 2009
- Measurement of apparent cell radii using a multiple wave vector diffusion experimentMagnetic Resonance in Medicine, 2009
- Compartment size estimation with double wave vector diffusion‐weighted imagingMagnetic Resonance in Medicine, 2008
- Locally anisotropic motion in a macroscopically isotropic system: displacement correlations measured using double pulsed gradient spin‐echo NMRMagnetic Resonance in Chemistry, 2002
- Multiple Scattering by NMRJournal of the American Chemical Society, 1999
- Multiple wave-vector extensions of the NMR pulsed-field-gradient spin-echo diffusion measurementPhysical Review B, 1995