Medical diagnosis at the point-of-care by portable high-field asymmetric waveform ion mobility spectrometry: a systematic review and meta-analysis
- 28 July 2021
- journal article
- review article
- Published by IOP Publishing in Journal of Breath Research
- Vol. 15 (4) , 046002
Abstract
Non-invasive medical diagnosis by analysing volatile organic compounds (VOCs) at the point-of-care is becoming feasible owing to recent advances in portable instrumentation. A number of studies have assessed the performance of a state-of-the-art VOC analyser (micro-chip high-field asymmetric waveform ion mobility spectrometry, FAIMS) for medical diagnosis. However, a comprehensive meta-analysis is needed to investigate the overall diagnostic performance of these novel methods across different medical conditions. An electronic search was performed using the CAplus and MEDLINE database through the SciFinder platform. The review identified a total of 23 studies and 2312 individuals. Eighteen studies were used for meta-analysis. A pooled analysis found an overall sensitivity of 80% (95% CI, 74%–85%, I 2 = 62%), and specificity of 78% (95% CI, 70%–84%, I 2 = 80%), which corresponds to the overall diagnostic performance of micro-chip FAIMS across many different medical conditions. The diagnostic accuracy was particularly high for coeliac and inflammatory bowel disease (sensitivity and specificity from 74% to 97%). The overall diagnostic performance was similar across breath, urine, and faecal matrices with sparse logistic regression and random forests algorithms resulting in higher diagnostic accuracy. Sources of variability likely arise from differences in sample storage, sampling protocol, method of data analysis, type of disease, sample matrix, and potentially to clinical and disease factors. The results of this meta-analysis indicate that micro-chip FAIMS is a promising candidate for disease screening at the point-of-care, particularly for gastroenterology diseases. This review provides recommendations that should improve the techniques relevant to diagnostic accuracy of future VOC and point-of-care studies.Keywords
Funding Information
- University of New South Wales
This publication has 68 references indexed in Scilit:
- Application of a Novel Tool for Diagnosing Bile Acid DiarrhoeaSensors, 2013
- The Human Urine MetabolomePLOS ONE, 2013
- Results of Initial Low-Dose Computed Tomographic Screening for Lung CancerNew England Journal of Medicine, 2013
- A Novel Tool for Noninvasive Diagnosis and Tracking of Patients with Inflammatory Bowel DiseaseInflammatory Bowel Diseases, 2013
- The scent of disease: volatile organic compounds of the human body related to disease and disorderThe Journal of Biochemistry, 2011
- Human exhaled air analytics: biomarkers of diseasesBiomedical Chromatography, 2007
- The case of the misleading funnel plotBMJ, 2006
- Comparison of Two Methods to Detect Publication Bias in Meta-analysisJAMA, 2006
- Diagnostic potential of breath analysis—focus on volatile organic compoundsClinica Chimica Acta, 2004
- The random subspace method for constructing decision forestsIEEE Transactions on Pattern Analysis and Machine Intelligence, 1998