Hematocrit-Independent Recovery is A Key for Bioanalysis Using Volumetric Absorptive Microsampling Devices, Mitra Tm
Authors:
- 21 August 2015
- journal article
- Published by Taylor & Francis in Bioanalysis
- Vol. 7 (15) , 1821-1829
Abstract
Background: A novel microsampling device, MitraTM, was evaluated for bioanalysis of E6005 and its O-desmethylated metabolite in human whole blood using an UPLC–MS. Results: A constant volume of blood samples was absorbed onto the tip of Mitra, the analytes were extracted by various solvents and then detected by UPLC–MS. Recovery of the analytes was high in acetonitrile–water (1:1, v/v) but was dependent on hematocrit (Hct) without sonication process, which led to biased accuracy at low and high Hcts. Inclusion of sonication process in extraction improved recovery at high Hct to yield acceptable accuracy across Hcts. Conclusion: Optimization of extraction process to achieve high recovery regardless of Hct is critical in accurate bioanalysis via Mitra.Keywords
This publication has 10 references indexed in Scilit:
- Validation of a UPLC–MS/MS method for the simultaneous determination of E6005, a phosphodiesterase 4 inhibitor, and its metabolite in human plasmaJournal of Chromatography B, 2015
- Quantitative bioanalysis of paracetamol in rats using volumetric absorptive microsampling (VAMS)Journal of Pharmaceutical and Biomedical Analysis, 2015
- What is The Right Blood Hematocrit Preparation Procedure for Standards and Quality Control Samples for Dried Blood Spot Analysis?Bioanalysis, 2015
- A Device for Dried Blood Microsampling in Quantitative Bioanalysis: Overcoming The Issues Associated Blood HematocritBioanalysis, 2014
- Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative BioanalysisAnalytical Chemistry, 2014
- Safety and efficacy of topical E6005, a phosphodiesterase 4 inhibitor, in Japanese adult patients with atopic dermatitis: Results of a randomized, vehicle‐controlled, multicenter clinical trialThe Journal of Dermatology, 2014
- The Effect of Hematocrit on Bioanalysis of DBS: Results from The EBF DBS-Microsampling ConsortiumBioanalysis, 2013
- Antipruritic Effect of the Topical Phosphodiesterase 4 Inhibitor E6005 Ameliorates Skin Lesions in a Mouse Atopic Dermatitis ModelThe Journal of Pharmacology and Experimental Therapeutics, 2013
- Evaluation of Glucuronide Metabolite Stability in Dried Blood SpotsBioanalysis, 2012
- The Effect of Hematocrit on Assay Bias When Using DBS Samples for The Quantitative Bioanalysis of DrugsBioanalysis, 2010