Volitional EMG Control of a Novel Powered Ankle Prosthesis: A Case Series on Muscle Selectivity and Biomechanical Consequences
Authors:
- Faranak RostamjoudFRFaranak Rostamjoud
- Mohamed AbdelbarMohamed Abdelbar
- Friðrika Björk ÞorkelsdóttirFÞFriðrika Björk Þorkelsdóttir
- Sophie ThieleSTSophie Thiele
- Anna Lára ÁrmannsdóttirAÁAnna Lára Ármannsdóttir
- Atli Örn SverrissonASAtli Örn Sverrisson
- Sigurður BrynjólfssonSBSigurður Brynjólfsson
- Kristín BriemKBKristín Briem
Open Access
- 24 June 2026
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 722
Abstract
This study investigated the feasibility and biomechanical effects of volitional electromyography (EMG)-based control of a powered transtibial ankle prosthesis. Four male participants completed static and dynamic EMG assessments and gait analysis while using both their prescribed passive prosthesis and an EMG-controlled powered prototype during level walking at self-selected and fast speeds, as well as ramp ascent and descent. Selective activation of residual tibialis anterior and gastrocnemius muscles was quantified using a co-contraction index, and lower-limb kinematics and kinetics were compared between prosthetic conditions. Participants were able to generate task-dependent residual muscle activity, supporting the feasibility of EMG-based volitional control. However, muscle selectivity was reduced during dynamic tasks, with higher co-contraction during gait than during seated static contractions, and substantial inter-subject variability was observed. Compared to the prescribed passive prosthesis, the EMG-controlled prototype generally produced lower prosthetic-side ankle range of motion and ankle power, although ankle moments were sometimes slightly greater. These findings suggest that EMG control is feasible, but that future controller design must remain flexible to individual users’ neuromuscular abilities and dynamic control limitations. The results provide important guidance for the development and testing of more adaptive, personalized, and functionally effective EMG-controlled prosthetic ankle systems.Keywords
Funding Information
- Icelandic Centre for Research (2215370-0611)
- Háskóli Íslands (RSJ2025-96411)
This publication has 36 references indexed in Scilit:
- A low-power ankle-foot prosthesis for push-off enhancementWearable Technologies, 2023
- Metabolic cost of transport and stance time asymmetry in individuals with unilateral transtibial amputation using a passive prostheses while walkingClinical Biomechanics, 2022
- Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directionsJournal of Neural Engineering, 2021
- Variable stiffness foot design and validationJournal of Biomechanics, 2021
- Identification of trunk and pelvis movement compensations in patients with transtibial amputation using angular momentum separationGait & Posture, 2016
- Within-socket myoelectric prediction of continuous ankle kinematics for control of a powered transtibial prosthesisJournal of Neural Engineering, 2014
- Gait variability and regularity of people with transtibial amputationsGait & Posture, 2013
- Gait characteristics of individuals with transtibial amputations walking on a destabilizing rock surfaceGait & Posture, 2012
- Strength asymmetry and osteoarthritis risk factors in unilateral trans-tibial, amputee gaitGait & Posture, 2010
- Compensatory mechanisms in below-knee amputee gait in response to increasing steady-state walking speedsGait & Posture, 2008