Comparison of conventional and castroviejo needle holders in terms of vascular anastomosis time in renal transplant
Open Access
- 30 September 2022
- journal article
- research article
- Published by Endouroloji Dernegi in Endouroloji Bulteni
- Vol. 14 (3) , 77-83
Abstract
Objective : It is important that the anastomosis time of renal vascular structures is not prolonged to minimize the potentially harmful effect of warm and cold ischemic times. This study aimed to determine the effect of the needle holder design used in vascular anastomosis during renal transplantation on the duration of anastomosis. Material and Methods : Patients that underwent renal transplantation at our clinic between September 2011 and February 2020, were divided into groups according to the two types of needle holders used in anastomoses. In Group 1, a conventional, Hegar-type, straight, 180-mm (7”) Ryder Diadust needle holder was used. In Group 2, a pen-type, straight, 215-mm (8 ½”) Castroviejo Durogrip TC micro needle holder was used. Demographic characteristics, vascular characteristics, and vascular anastomosis times were compared between the two groups. Results : A total of 75 patients were included in the study. There were 39 (52%) patients in Group 1 and 36 (48%) patients in Group 2. The mean number of arteries was 1.2 ± 0.4, and the mean arterial diameter was 5.3 ± 1.2 mm in the whole cohort, with no statistically significant difference between the two groups (p=0.196 and 0.304, respectively). The mean arterial anastomosis time was 15 ± 5.1 minutes in Group 1 and 10 ± 3.9 minutes in Group 2. The mean venous anastomosis times were 18.4 ± 6.1 in Group 1 and 14.7 ± 4 minutes in Group 2. In the statistical analysis, the arterial and vein anastomosis times were found to be significantly shorter in Group 2 than in Group 1 (p=0.038 and p=0.020, respectively). Conclusion : In our study, it was observed that the renal arterial and venous anastomosis times were significantly shorter in the group in which the pen-type Castroviejo needle holder was used in anastomoses performed during renal transplantation.Keywords
This publication has 18 references indexed in Scilit:
- The Effect of Anastomosis Time on Outcome in Recipients of Kidneys Donated After Brain Death: A Cohort StudyAmerican Journal of Transplantation, 2015
- Frimand Needle Holder Reduces Suturing Time and Surgical Stress When Suturing in Palm GripSurgical Innovation, 2015
- The impact of vascular anastomosis time on early kidney transplant outcomesTransplantation Research, 2013
- Deleterious Influence of Prolonged Warm Ischemia in Living Donor Kidney TransplantationTransplantation Proceedings, 2012
- Every Minute Counts When the Renal Hilum Is Clamped During Partial NephrectomyEuropean Urology, 2010
- Assessing the Impact of Ischaemia Time During Partial NephrectomyEuropean Urology, 2009
- Conversion of Working Memory to Motor Sequence in the Monkey Premotor CortexScience, 2003
- Improvement of the laparoscopic needle holder based on new ergonomic guidelinesSurgical Endoscopy, 2003
- A needle holder for vascular and plastic surgeryThe American Journal of Surgery, 1976
- FUNCTIONS OF A TRANSPLANTED KIDNEYScience, 1905