Separating arterial and venous components from 3D dynamic contrast‐enhanced MRI studies using factor analysis
Authors:
Open Access
- 15 April 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (5) , 928-933
Abstract
Dynamic contrast‐enhanced MRI has been used extensively for angiography but in order to generate separate arterial and venous images some form of postprocessing is required. This typically involves the subtraction of one image in a dynamic sequence from another in order to suppress unwanted signal; however, this also has the effect of decreasing the signal‐to‐noise ratio (SNR) of the image. In this study, factor analysis, a technique related to eigenimage filtering, is used to separate arterial and venous components from dynamic contrast‐enhanced images of the legs acquired with a temporal resolution of 30 sec. The SNR of the venous and arterial images extracted from a series of 20 patients using conventional single subtraction, a double subtraction method, and factor analysis were compared. Results show that the use of factor analysis improved the SNR in the venous images by a factor of 2.3 compared with the use of simple subtraction. A subjective comparison of the maximum intensity projection images generated from the venous images was also carried out and showed a significant preference for those generated using factor analysis over those generated using other subtraction methods. Magn Reson Med 49:928–933, 2003.Keywords
This publication has 13 references indexed in Scilit:
- Confirmatory aspects in factor analysis of image sequences2005
- Deep Venous Thrombosis: Diagnosis by Using Venous Enhanced Subtracted Peak Arterial MR Venography versus Conventional VenographyRadiology, 2003
- MRA of the lower extremities in patients with pulmonary embolism using a blood pool contrast agent: initial experience.Journal of Magnetic Resonance Imaging, 2002
- Segmentation with gray‐scale connectedness can separate arteries and veins in MRAJournal of Magnetic Resonance Imaging, 2002
- Combined time‐resolved and high‐spatial‐resolution 3D MRA using an extended adaptive acquisitionJournal of Magnetic Resonance Imaging, 2002
- Diagnosis of Lower-Limb Deep Venous Thrombosis: A Prospective Blinded Study of Magnetic Resonance Direct Thrombus ImagingAnnals of Internal Medicine, 2002
- Artery-vein separation via MRA-An image processing approachIEEE Transactions on Medical Imaging, 2001
- Gadolinium-enhanced body MR venography with subtraction technique.American Journal of Roentgenology, 1997
- Correlation Between Contrast Enhancement in Dynamic Magnetic Resonance Imaging of the Breast and Tumor AngiogenesisInvestigative Radiology, 1994
- Eigenimage Filtering in MR ImagingJournal of Computer Assisted Tomography, 1988