EEG Signal Quality of a Subcutaneous Recording System Compared to Standard Surface Electrodes
Open Access
- 1 January 2015
- journal article
- research article
- Published by Hindawi Limited in Journal of Sensors
- Vol. 2015, 1-9
Abstract
Purpose. We provide a comprehensive verification of a new subcutaneous EEG recording device which promises robust and unobtrusive measurements over ultra-long time periods. The approach is evaluated against a state-of-the-art surface EEG electrode technology.Materials and Methods. An electrode powered by an inductive link was subcutaneously implanted on five subjects. Surface electrodes were placed at sites corresponding to the subcutaneous electrodes, and the EEG signals were evaluated with both quantitative (power spectral density and coherence analysis) and qualitative (blinded subjective scoring by neurophysiologists) analysis.Results. The power spectral density and coherence analysis were very similar during measurements of resting EEG. The scoring by neurophysiologists showed a higher EEG quality for the implanted system for different subject states (eyes open and eyes closed). This was most likely due to higher amplitude of the subcutaneous signals. During periods with artifacts, such as chewing, blinking, and eye movement, the two systems performed equally well.Conclusions. Subcutaneous measurements of EEG with the test device showed high quality as measured by both quantitative and more subjective qualitative methods. The signal might be superior to surface EEG in some aspects and provides a method of ultra-long term EEG recording in situations where this is required and where a small number of EEG electrodes are sufficient.Keywords
Funding Information
- The Danish Council for Strategic Research
This publication has 11 references indexed in Scilit:
- Subdural to subgaleal EEG signal transmission: The role of distance, leakage and insulating affectorsClinical Neurophysiology, 2013
- Prediction of seizure likelihood with a long-term, implanted seizure advisory system in patients with drug-resistant epilepsy: a first-in-man studyThe Lancet Neurology, 2013
- Detection of hypoglycemia associated EEG changes during sleep in type 1 diabetes mellitusDiabetes Research and Clinical Practice, 2012
- Wearable ElectroencephalographyIEEE Engineering in Medicine and Biology Magazine, 2010
- Automated detection of hypoglycemia-induced EEG changes recorded by subcutaneous electrodes in subjects with type 1 diabetes—The brain as a biosensorDiabetes Research and Clinical Practice, 2010
- Electro-mechanical stability of surface EMG sensorsMedical & Biological Engineering & Computing, 2007
- Evolution in impedance at the electrode-skin interface of two types of surface EMG electrodes during long-term recordingsJournal of Electromyography and Kinesiology, 2003
- An automatic ambulatory device for detection of AASM defined arousals from sleep: the WP100Sleep Medicine, 2003
- EEG Topography during Insulin-Induced Hypoglycemia in Patients with Insulin-Dependent Diabetes mellitusEuropean Neurology, 1996
- Über das Elektrenkephalogramm des MenschenEuropean Archives of Psychiatry and Clinical Neuroscience, 1933