Proton irradiation of a swept charge device at cryogenic temperature and the subsequent annealing
Authors:
- 1 January 2015
- journal article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 10 (01) , C01037
Abstract
A number of studies have demonstrated that a room temperature proton irradiation may not be sufficient to provide an accurate estimation of the impact of the space radiation environment on detector performance. This is a result of the relationship between defect mobility and temperature, causing the performance to vary subject to the temperature history of the device from the point at which it was irradiated. Results measured using Charge Coupled Devices (CCD) irradiated at room temperature therefore tend to differ from those taken when the device was irradiated at a cryogenic temperature, more appropriate considering the operating conditions in space, impacting the prediction of in-flight performance. This paper describes the cryogenic irradiation, and subsequent annealing of an e2v technologies Swept Charge Device (SCD) CCD236 irradiated at −35.4°C with a 10 MeV equivalent proton fluence of 5.0 × 108 protons · cm−2. The CCD236 is a large area (4.4 cm2) X-ray detector that will be flown on-board the Chandrayaan-2 and Hard X-ray Modulation Telescope spacecraft, in the Chandrayaan-2 Large Area Soft X-ray Spectrometer and the Soft X-ray Detector respectively. The SCD is readout continually in order to benefit from intrinsic dither mode clocking, leading to suppression of the surface component of the dark current and allowing the detector to be operated at warmer temperatures than a conventional CCD. The SCD is therefore an excellent choice to test and demonstrate the variation in the impact of irradiation at cryogenic temperatures in comparison to a more typical room temperature irradiation.Keywords
This publication has 19 references indexed in Scilit:
- Measurement of the effect of non ionising energy losses on the leakage current of silicon drift detector prototypes for the LOFT satelliteJournal of Instrumentation, 2014
- CMOS sensor and camera for the PHI instrument on board Solar Orbiter: evaluation of the radiation tolerance2012
- Effects of Low Temperature Proton Irradiation on a Large Area CCD for Astrometric ApplicationsIEEE Transactions on Nuclear Science, 2010
- Low Temperature Alpha Particle Irradiation of a STAR1000 CMOS APSIEEE Transactions on Nuclear Science, 2008
- Physics of reverse annealing in high-resistivity Chandra ACIS CCDs2008
- CCD Radiation Testing at Low Temperatures Using a Laboratory Alpha Particle SourceIEEE Transactions on Nuclear Science, 2006
- Hot pixel annealing behavior in CCDs irradiated at -84/spl deg/CIEEE Transactions on Nuclear Science, 2005
- Radiation effects on astrometric CCDs at low operating temperaturesIEEE Transactions on Nuclear Science, 2005
- Anomalous annealing of a high-resistivity CCD irradiated at low temperatureIEEE Transactions on Nuclear Science, 2005
- Hot pixel behavior in WFC3 CCD detectors irradiated under operational conditions2004