Enhancement of functional MRI signal at high‐susceptibility regions of brain using simultaneous multiecho multithin‐slice summation imaging technique
Authors:
Open Access
- 28 January 2016
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (2) , 478-485
Abstract
Purpose: To increase temporal‐signal‐to‐noise ratio (tSNR) and blood oxygen level‐dependent (BOLD) sensitivity at high‐susceptibility regions of the brain by means of a simultaneous multiecho multithin‐slice summation imaging technique.Materials and Methods: The simultaneous multislice (SMS) technique was implemented with multiecho (SMSME) and multiecho with thin‐slice summation (SMSME‐thin) at 3T. Multiecho data were summated based on the local apparent weighting factor. Ten healthy subjects were studied for the whole brain activation by breath‐holding. The tSNR values and the number of activated pixels acquired with SMSME and SMSME‐thin were compared with those acquired with the conventional gradient‐echo EPI in multiple brain regionsResults: SMS methods accelerated imaging time by 5‐fold as compared with the conventional method, resulting in the acquisition of three echoes and four thin‐slices during the same TR of 2.5 seconds. At high‐susceptibility regions, including the amygdala, inferior and middle temporal, and anterior frontal lobes, SMSME increased tSNR values by up to ∼80% and BOLD activation by up to ∼20% (paired t‐test, P < 0.05). SMSME‐thin further increased values as compared with SMSME (∼45% for tSNR and ∼20% for activation, P < 0.05).Conclusion: The SMSME‐thin imaging technique enhanced the temporal‐signal‐to‐noise ratio and functional activation at high susceptibility regions of the brain. J. Magn. Reson. Imaging 2016;44:478–485.Keywords
Funding Information
- Radiological Society of North America (RSNA) (RSCH1314)
This publication has 23 references indexed in Scilit:
- Interslice leakage artifact reduction technique for simultaneous multislice acquisitionsMagnetic Resonance in Medicine, 2013
- Multi-slice parallel transmission three-dimensional tailored RF (PTX 3DTRF) pulse design for signal recovery in ultra high field functional MRIJournal of Magnetic Resonance, 2013
- Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penaltyMagnetic Resonance in Medicine, 2011
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- BOLD contrast sensitivity enhancement and artifact reduction with multiecho EPI: Parallel‐acquired inhomogeneity‐desensitized fMRIMagnetic Resonance in Medicine, 2006
- Improved BOLD detection in the medial temporal region using parallel imaging and voxel volume reductionNeuroImage, 2006
- Susceptibility-Induced Loss of Signal: Comparing PET and fMRI on a Semantic TaskNeuroImage, 2000
- Functional MRI of human brain activation at high spatial resolutionMagnetic Resonance in Medicine, 1993
- Reduction of susceptibility artifact in gradient‐echo imagingMagnetic Resonance in Medicine, 1992
- Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensationMagnetic Resonance in Medicine, 1988