Assessing vascular response to exercise using a combination of real‐time spiral phase contrast MR and noninvasive blood pressure measurements
Open Access
- 29 March 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 31 (4) , 997-1003
Abstract
Purpose: To measure the hemodynamic response to exercise using real‐time velocity mapping magnetic resonance imaging (MRI), incorporating a high temporal resolution spiral phase contrast (PC) sequence accelerated with sensitivity encoding (SENSE).Materials and Methods: Twenty healthy adults underwent MRI at rest and during supine exercise at two different exercise levels. Flow volumes were assessed in the ascending aorta using a spiral SENSE real‐time PC sequence. The sequence was validated at rest against a vendor supplied gated PC sequence, and also at rest and during exercise against left ventricular volumes assessed using a radial k‐t SENSE real‐time sequence. Combining the measured flow volumes with simultaneous oscillometric blood pressure measurements, enabled the noninvasive calculations of systemic vascular resistance (SVR) and arterial compliance (C).Results: Measured flow volumes correlated very well between the sequences at rest and during exercise. Cardiac output (CO) and heart rate were found to significantly increase during exercise, while SVR and C were found to decrease significantly.Conclusion: Hemodynamic response to exercise can be accurately quantified using a high temporal resolution spiral SENSE real‐time flow imaging. This may allow early detection of hypertension and a greater understanding of the early changes in this condition. J. Magn. Reson. Imaging 2010;31:997–1003. ©2010 Wiley‐Liss, Inc.Keywords
This publication has 21 references indexed in Scilit:
- Feasibility and reproducibility of biventricular volumetric assessment of cardiac function during exercise using real‐time radial k‐t SENSE magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2009
- Measurement of total pulmonary arterial compliance using invasive pressure monitoring and MR flow quantification during MR-guided cardiac catheterizationAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Novel Method of Quantifying Pulmonary Vascular Resistance by Use of Simultaneous Invasive Pressure Monitoring and Phase-Contrast Magnetic Resonance FlowCirculation, 2004
- Flow during exercise in the total cavopulmonary connection measured by magnetic resonance velocity mappingHeart, 2002
- Exercise MR Imaging in the Assessment of Pulmonary Regurgitation and Biventricular Function in Patients after Tetralogy of Fallot RepairRadiology, 2002
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Quantitative abdominal aortic flow measurements at controlled levels of ergometer exerciseMagnetic Resonance Imaging, 1999
- Blood Pressure Response During Treadmill Testing as a Risk Factor for New-Onset HypertensionCirculation, 1999
- Assessment of Coronary Arterial Flow and Flow Reserve in Humans With Magnetic Resonance ImagingCirculation, 1996
- Real time blood flow imaging by spiral scan phase velocity mappingMagnetic Resonance in Medicine, 1994