A Printed Equilibrium Dialysis Device with Integrated Membranes for Improved Binding Affinity Measurements
Authors:
- 25 June 2017
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (14) , 7302-7306
Abstract
Equilibrium dialysis is a simple and effective technique used for investigating the binding of small molecules and ions to proteins. A three-dimensional (3D) printer was used to create a device capable of measuring binding constants between a protein and a small ion based on equilibrium dialysis. Specifically, the technology described here enables the user to customize an equilibrium dialysis device to fit their own experiments by choosing membranes of various material and molecular-weight cutoff values. The device has dimensions similar to that of a standard 96-well plate, thus being amenable to automated sample handlers and multichannel pipettes. The device consists of a printed base that hosts multiple windows containing a porous regenerated-cellulose membrane with a molecular-weight cutoff of ∼3500 Da. A key step in the fabrication process is a print-pause-print approach for integrating membranes directly into the windows subsequently inserted into the base. The integrated membranes display no leaking upon placement into the base. After characterizing the system’s requirements for reaching equilibrium, the device was used to successfully measure an equilibrium dissociation constant for Zn2+ and human serum albumin (Kd = (5.62 ± 0.93) × 10–7 M) under physiological conditions that is statistically equal to the constants reported in the literature.Keywords
Funding Information
- National Institute of Diabetes and Digestive and Kidney Diseases (DK110665)
- National Institute of General Medical Sciences (GM110406)
This publication has 26 references indexed in Scilit:
- One-Step Fabrication of a Microfluidic Device with an Integrated Membrane and Embedded Reagents by Multimaterial 3D PrintingAnalytical Chemistry, 2017
- 3D Printed Micrometer-Scale Polymer Mounts for Single Crystal AnalysisAnalytical Chemistry, 2017
- Recent Advances in Analytical Chemistry by 3D PrintingAnalytical Chemistry, 2016
- 3D-printed microfluidic devices: fabrication, advantages and limitations—a mini reviewAnalytical Methods, 2016
- Use of electrospinning and dynamic air focusing to create three-dimensional cell culture scaffolds in microfluidic devicesThe Analyst, 2016
- Analysis of drug–protein binding by ultrafast affinity chromatography using immobilized human serum albuminJournal of Chromatography A, 2010
- Addressing a vascular endothelium array with blood components using underlying microfluidic channelsLab on a Chip, 2007
- Determination of the Affinity of Drugs toward Serum Albumin by Measurement of the Quenching of the Intrinsic Tryptophan Fluorescence of the ProteinJournal of Pharmacy and Pharmacology, 1999
- Determination of Rate and Equilibrium Binding Constants for Macromolecular Interactions Using Surface Plasmon Resonance: Use of Nonlinear Least Squares Analysis MethodsAnalytical Biochemistry, 1993
- Binding of cadmium(II) and zinc(II) to human and dog serum albumins. An equilibrium dialysis and 113Cd-NMR studyBiochemistry and Cell Biology, 1991