Design and simulation of a semiconductor detector-based Compton imaging system with efficiency analysis
Authors:
Preprint
- 27 February 2023
- preprint
- Published by Springer Nature in Research Square
Abstract
In recent years, Compton cameras that use electronic collimators have become common. One or more scatterer detectors and an absorber detector make up the Compton camera, which is sensitive to the energy and location of scattered gamma rays. It predicts the distribution of gamma-ray sources by reflecting all valid events in the image space using conical surfaces. Compton cameras are designed for specific applications and image reconstruction using various methods. Based on studies on the efficiency of the Compton camera, the current work provides a novel detector design that includes scatterer and absorber detectors. This design includes eight scatterer detectors spaced 1 mm apart and an absorber detector 30 mm from the last scatterer detector. The distance between the source and the first scatterer detector was 5 mm. The scatterer and absorber detector plates were 70x70x2.125mm3 and 70x70x10mm3, respectively. The Compton imaging system is simulated using the GEANT4 toolkit. In addition, this study uses an analytical method to reconstruct Compton camera images. The method used for analytical reconstruction in the Compton imaging system differs slightly from simple restoration methods used in other imaging systems. In the analytical method, the equation related to the data reflected by the image must be solved to reconstruct the image directly. This method, the C + + code was developed to reconstruct Compton camera images. According to the results, using the analytical method to identify the best circumstances and the parameters impacting efficiency, the value of FWHM achieved was 3.7 mm with an angular uncertainty of about 2.7 at an energy of 0.662 MeV. Furthermore, the FWHM value decreased by 0.7 mm, compared to another (experimental) design that employed the analytical image reconstruction approach.Keywords
All Related Versions
This publication has 24 references indexed in Scilit:
- Development of a Compton camera for prompt-gamma medical imagingRadiation Physics and Chemistry, 2017
- First demonstration of multi-color 3-D in vivo imaging using ultra-compact Compton cameraScientific Reports, 2017
- Tests of a Compton imaging prototype in a monoenergetic 4.44 MeV photon field—a benchmark setup for prompt gamma-ray imaging devicesJournal of Instrumentation, 2016
- Statistical performance evaluation and comparison of a Compton medical imaging system and a collimated Anger camera for higher energy photon imagingPhysics in Medicine & Biology, 2008
- Multiple molecular simultaneous imaging in a live mouse using semiconductor Compton cameraJournal of Analytical Atomic Spectrometry, 2008
- Potential of a Compton camera for high performance scintimammographyPhysics in Medicine & Biology, 2004
- Application of spherical harmonics to image reconstruction for the Compton cameraPhysics in Medicine & Biology, 1998
- An electronically collimated gamma camera for single photon emission computed tomography. Part II: Image reconstruction and preliminary experimental measurementsMedical Physics, 1983
- A three crystal NaI(Tl) gamma-ray scintillation spectrometerNuclear Instruments and Methods, 1964
- Measurement of Gamma-Ray Energies with Two Crystals in CoincidencePhysical Review B, 1950