What we have achieved in the design of 3D printed metal implants for application in orthopedics? Personal experience and review
- 18 October 2018
- journal article
- review article
- Published by Emerald Publishing in Rapid Prototyping Journal
- Vol. 24 (8) , 1365-1379
Abstract
Purpose: This paper aims to review the latest applications in terms of three-dimensional printed (3DP) metal implants in orthopedics, and, importantly, the design of 3DP metal implants through a series of cases operated at The Second Hospital of Jilin University were presented.Design/methodology/approach: This paper is available to practitioners who are use 3DP implants in orthopedics. This review began with the deficiency of traditional prostheses and basic concepts of 3DP implants. Then, representative 3DP clinical cases were summarized and compared, and the experiences using customized prostheses and directions for future potential development are also shown.Findings: The results obtained from the follow-up of clinical applications of 3DP implants show that the 3D designed and printed metal implants could exhibit good bone defect matching, quick and safe joint functional rehabilitation as well as saving time in surgery, which achieved high patient satisfaction collectively.Originality/value: Single center experiences of 3DP metal implants design were shared and the detailed technical points between various regions were compared and analyzed. In conclusion, the 3DP technology is infusive and will present huge potential to reform future orthopedic practice.Keywords
This publication has 77 references indexed in Scilit:
- Revision of Complex Acetabular Defects Using Cages with the Aid of Rapid PrototypingThe Journal of Arthroplasty, 2013
- The effect of pore geometry on the in vitro biological behavior of human periosteum-derived cells seeded on selective laser-melted Ti6Al4V bone scaffoldsActa Biomaterialia, 2012
- Proximaler Tibiaersatz und alloplastische Rekonstruktion des Streckapparats nach Resektion kniegelenksnaher TumorenOperative Orthopädie und Traumatologie, 2012
- Management of Bone Defects in Revision Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2012
- Antibacterial and anti-adhesive zeolite coatings on titanium alloy surfaceMicroporous and Mesoporous Materials, 2011
- Characterization of cellular solids in Ti6Al4V for orthopaedic implant applications: Trabecular titaniumJournal of the Mechanical Behavior of Biomedical Materials, 2010
- Total shoulder arthroplasty: Downward inclination of the glenoid component to balance supraspinatus deficiencyJournal of Shoulder and Elbow Surgery, 2009
- Peri-acetabular resection and endoprosthetic reconstruction for tumours of the acetabulumThe Journal of Bone and Joint Surgery. British volume, 2008
- Evaluation of a Porous Tantalum Uncemented Acetabular Cup in Revision Total Hip ArthroplastyThe Journal of Arthroplasty, 2005
- Radiographic Evaluation of a Monoblock Acetabular ComponentThe Journal of Arthroplasty, 2005