Stroke type differentiation using spectrally constrained multifrequency EIT: evaluation of feasibility in a realistic head model
Authors:
- Markus JehlMJMarkus Jehl
- Simon ArridgeSASimon Arridge
- Timo BetckeTBTimo Betcke
- David HolderDHDavid Holder
Open Access
- 20 May 2014
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 35 (6) , 1051-1066
Abstract
We investigate the application of multifrequency electrical impedance tomography (MFEIT) to imaging the brain in stroke patients. The use of MFEIT could enable early diagnosis and thrombolysis of ischaemic stroke, and therefore improve the outcome of treatment. Recent advances in the imaging methodology suggest that the use of spectral constraints could allow for the reconstruction of a one-shot image. We performed a simulation study to investigate the feasibility of imaging stroke in a head model with realistic conductivities. We introduced increasing levels of modelling errors to test the robustness of the method to the most common sources of artefact. We considered the case of errors in the electrode placement, spectral constraints, and contact impedance. The results indicate that errors in the position and shape of the electrodes can affect image quality, although our imaging method was successful in identifying tissues with sufficiently distinct spectra.Keywords
This publication has 21 references indexed in Scilit:
- The impact of electrode area, contact impedance and boundary shape on EIT imagesPhysiological Measurement, 2011
- A generic interface for parallel and adaptive discretization schemes: abstraction principles and the Dune-Fem moduleComputing, 2010
- An electrode addressing protocol for imaging brain function with electrical impedance tomography using a 16-channel semi-parallel systemPhysiological Measurement, 2009
- Large-Scale Non-Linear 3D Reconstruction Algorithms for Electrical Impedance Tomography of the Human Head2007
- Temperature Dependence of Tissue Impedivity in Electrical Impedance Tomography of CryosurgeryIEEE Transactions on Biomedical Engineering, 2005
- Assessment of errors in static electrical impedance tomography with adjacent and trigonometric current patternsPhysiological Measurement, 1997
- Multifrequency and parametric EIT images of neonatal lungsPhysiological Measurement, 1995
- Measured and expected Cole parameters from electrical impedance tomographic spectroscopy images of the human thoraxPhysiological Measurement, 1995
- Detection of cerebral ischaemia in the anaesthetised rat by impedance measurement with scalp electrodes: implications for non-invasive imaging of stroke by electrical impedance tomographyClinical Physics and Physiological Measurement, 1992
- Brain extracellular space during spreading depression and ischemiaActa Physiologica Scandinavica, 1980