Optimal sensor placement of bridge structure based on sensitivity‐effective independence method
Authors:
Open Access
- 11 May 2021
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Circuits, Devices & Systems
- Vol. 16 (2) , 125-135
Abstract
Taking the optimal sensor placement problem in bridge structural health monitoring as the study object and relying on the engineering example of a simply supported steel truss bridge, the improved optimal sensor placement method based on sensitivity‐effective independence method was proposed. Using the sensitivity coefficient reflecting structural damage, the proposed method could modify the effective independence method reflecting the maximum linear independence. The proposed method further optimizes the sensor placement method. A method for selecting the number of models based on modal closeness was proposed and makes the selection of the number of modes more objective. The example analysis shows that evaluations using this method are effective for multiple evaluation criteria. The method ensures observability of the mode vector and identifiability of structural damage. It is an effective optimal sensor placement algorithm for the bridge structure.Keywords
This publication has 25 references indexed in Scilit:
- Optimal sensor placement in structural health monitoring using discrete optimizationSmart Materials and Structures, 2015
- Sensor placement optimization for structural modal identification of flexible structures using genetic algorithmJournal of Mechanical Science and Technology, 2015
- Structural Damage Detection Using Modal Strain Energy and Hybrid Multiobjective OptimizationComputer-Aided Civil and Infrastructure Engineering, 2015
- A Bee Swarm Algorithm for Optimising Sensor Distributions for Impact Detection on a Composite PanelStrain, 2015
- Optimal sensor placement for health monitoring of high-rise structure using adaptive monkey algorithmStructural Control and Health Monitoring, 2014
- Energy-aware wireless sensor placement in structural health monitoring using hybrid discrete firefly algorithmStructural Control and Health Monitoring, 2014
- Health monitoring sensor placement optimization for Canton Tower using immune monkey algorithmStructural Control and Health Monitoring, 2014
- Robustness of optimal sensor placement under parametric uncertaintyMechanical Systems and Signal Processing, 2013
- Optimal sensor placement for structural health monitoring based on multiple optimization strategiesThe Structural Design of Tall and Special Buildings, 2011
- The connection between effective independence and modal kinetic energy methods for sensor placementJournal of Sound and Vibration, 2007